Office-Based 25-Gauge Needle Revision of Closed Peripheral Iridotomy in Aphakic Silicone Oil-Filled Eyes.

Nudleman Sebastian, Feiner Ella R, Affeldt Stella, Prenner Jonathan L

СтатьяПеревод в очереди

Аннотация

PURPOSE: We present a novel office-based technique using a 25-gauge needle to reopen closed peripheral iridotomies in aphakic eyes filled with silicone oil.

METHODS

We use a 25-gauge needle to enter the clear cornea and reopen the closed peripheral iridotomy, allowing for aqueous humor and silicone oil to escape and relieve elevated intraocular pressure.

RESULTS

This minimally invasive office-based approach provides immediate relief of elevated intraocular pressure due to silicone oil-induced pupillary block, avoiding the need for more invasive surgical intervention.

CONCLUSION

Our technique is a simple, cost-effective, and accessible way to combat silicone-oil induced pupillary block in aphakic patients and may be a good first-line approach for a difficult-to-manage condition.

Для цитирования: Nudleman Sebastian, Feiner Ella R, Affeldt Stella, Prenner Jonathan L. Office-Based 25-Gauge Needle Revision of Closed Peripheral Iridotomy in Aphakic Silicone Oil-Filled Eyes.. Retina (Philadelphia, Pa.). 2025. DOI: 10.1097/iae.0000000000004464.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.