MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajodo.2014.04.022

Медицинская библиотека · American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics · 2014

Bone stress and strain after use of a miniplate for molar protraction and uprighting: a 3-dimensional finite element analysis.

Largura Lucila Zimmermann, Argenta Marco André, Sakima Maurício Tatsuei, Camargo Elisa Souza, Guariza-Filho Odilon, Tanaka Orlando Motohiro

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

The aim of this study was to use the finite element method to evaluate the distribution of stresses and strains on the local bone tissue adjacent to the miniplate used for anchorage of orthodontic forces.

METHODS

A 3-dimensional model composed of a hemimandible and teeth was constructed using dental computed tomographic images, in which we assembled a miniplate with fixation screws. The uprighting and mesial movements of the mandibular second molar that was anchored with the miniplate were simulated. The miniplate was loaded with horizontal forces of 2, 5, and 15 N. A moment of 11.77 N·mm was also applied. The stress and strain distributions were analyzed, and their correlations with the bone remodeling criteria and miniplate stability were assessed.

RESULTS

When orthodontic loads were applied, peak bone strain remained within the range of bone homeostasis (100-1500 μ strain) with a balance between bone formation and resorption. The maximum deformation was found to be 1035 μ strain with a force of 5 N. At a force of 15 N, bone resorption was observed in the region of the screws.

CONCLUSIONS

We observed more stress concentration around the screws than in the cancellous bone. The levels of stress and strain increased when the force was increased but remained within physiologic levels. The anchorage system of miniplate and screws could withstand the orthodontic forces, which did not affect the stability of the miniplate.

Для цитирования: Largura Lucila Zimmermann, Argenta Marco André, Sakima Maurício Tatsuei, Camargo Elisa Souza, Guariza-Filho Odilon, Tanaka Orlando Motohiro. Bone stress and strain after use of a miniplate for molar protraction and uprighting: a 3-dimensional finite element analysis.. American journal of orthodontics and dentofacial orthopedics : official publication of the American Association of Orthodontists, its constituent societies, and the American Board of Orthodontics. 2014. DOI: 10.1016/j.ajodo.2014.04.022.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.