MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1038/s41598-025-92118-1

Медицинская библиотека · Scientific reports · 2025

Development of anti-fouling endoscope tip hood for gastrointestinal endoscopy.

Shimamoto Yusaku, Morita Yoshinori, Matsunaga Toru, Hino Shiori, Sato Takao, Takao Madoka, Kodama Yuzo

СтатьяПеревод пока не подготовлен

Аннотация

The contamination of the endoscope tip lens results in poor endoscopic imaging. To prevent the adsorption of contaminants, we applied a soft contact lens made of 2-hydroxyethyl methacrylate hydrogel to the tip of a gastrointestinal endoscope. Additionally, a novel endoscopic hood with an upper surface composed of a single layer inside the hood cavity was developed. For in vitro anti-fouling performance testing using blood, changes in light transmittance were examined with hydrogel plates and compared to conventional quartz glass and surfactant-coated glass. The transmittance changes at a wavelength of 415 nm were 1.5% for the hydrogel plate, significantly lower than 82.9% for quartz glass and 85.2% for surfactant-coated glass (p < 0.001), demonstrating the hydrogel's high anti-fouling performance. Another in vitro quantitative assay, evaluated by exposure to blood, lipid, and mucin liquids, showed high anti-fouling performance in the order hydrogel plate > surfactant-coated glass > quartz glass. Moreover, an in vivo pig model performing gastric endoscopic submucosal dissection was used to evaluate anti-fouling performance by analyzing endoscopic images with Michelson contrast. The contrast value of the upper surface group (Hydrogel) was 0.97, significantly higher than 0.62 for the non-upper surface group (Surfactant) (P < 0.001). Therefore, the novel anti-fouling endoscope tip hood could be applied in future clinical applications.

Для цитирования: Shimamoto Yusaku, Morita Yoshinori, Matsunaga Toru, Hino Shiori, Sato Takao, Takao Madoka, Kodama Yuzo. Development of anti-fouling endoscope tip hood for gastrointestinal endoscopy.. Scientific reports. 2025. DOI: 10.1038/s41598-025-92118-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.