DOI 10.1016/j.jneumeth.2025.110461

Медицинская библиотека · Journal of neuroscience methods · 2025

Proper reference selection and re-referencing to mitigate bias in single pulse electrical stimulation data.

Huang Harvey, Adkinson Joshua A, Jensen Michael A, Hasen Mohammed, Danstrom Isabel A, Bijanki Kelly R, Gregg Nicholas M, Miller Kai J, Sheth Sameer A, Hermes Dora, Bartoli Eleonora

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Single pulse electrical stimulation experiments produce brain stimulation evoked potentials used to infer brain connectivity. The choice of recording reference for intracranial electrodes remains non-standardized and can significantly impact data interpretation. When the reference electrode is affected by stimulation or evoked brain activity, it can contaminate the brain stimulation evoked potentials recorded at all other electrodes and influence interpretation of findings.

NEW METHOD: This specific issue is highlighted in intracranial EEG datasets from two subjects recorded at separate institutions. We present several intuitive metrics to detect the presence of reference contamination, based on artificial similarity between all channels. We also offer practical guidance on mitigating contamination, by switching to a more neutral reference electrode, or by post hoc re-referencing, per stimulation site, to an adjusted common average that is optimized for bias and noise.

RESULTS

Either switching the reference electrode or re-referencing to an adjusted common average effectively mitigated the reference contamination issue. This was evidenced by metrics that indicated increased variability in the latencies and response durations of brain stimulation evoked potentials across the brain, and by increased similarity between experimental runs after re-referencing.

CONCLUSION

Overall, this study demonstrates the necessity of clear quality checks and preprocessing steps to ensure accurate interpretation of single pulse electrical stimulation data, and it provides a set of statistics and tools to achieve this.

Для цитирования: Huang Harvey, Adkinson Joshua A, Jensen Michael A, Hasen Mohammed, Danstrom Isabel A, Bijanki Kelly R, Gregg Nicholas M, Miller Kai J, Sheth Sameer A, Hermes Dora, Bartoli Eleonora. Proper reference selection and re-referencing to mitigate bias in single pulse electrical stimulation data.. Journal of neuroscience methods. 2025. DOI: 10.1016/j.jneumeth.2025.110461.