Journal of minimally invasive gynecology · 2020
Suture Complication Rates and Surgical Outcomes According to the Nonabsorbable Suture Materials Used in Vaginal Uterosacral Ligament Suspension: Polyester versus Polypropylene.
СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lee Jeesun, Oh Sumin, Jeon Myung Jae
Аннотация
STUDY OBJECTIVE: To evaluate suture complication rates and surgical outcomes according to the nonabsorbable suture materials used in vaginal uterosacral ligament suspension (USLS) surgery. Multifilament polyester (polyethylene terephthalate [PET]) and monofilament polypropylene (PP) sutures were compared.
DESIGN: Retrospective cohort study.
SETTING: Single teaching hospital.
PATIENTS: Total of 229 patients who underwent transvaginal USLS and completed a 1-year follow-up.
INTERVENTIONS: Use of PET and PP sutures for transvaginal USLS procedures.
MEASUREMENTS AND MAIN RESULTS: PP sutures were used in 149 patients, and PET sutures were used in 80 patients. The suture-related complication rates, including granulation tissue and suture erosion at the vaginal apex, were significantly higher in the PET suture group than in the PP suture group (46.3% vs 20.1%, p <.01). However, there was no significant difference in the rates of surgical failure (defined as the presence of vaginal bulging symptoms, apical descent ≥ half of the total vaginal length, anterior or posterior vaginal wall descent beyond the hymen, or retreatment for prolapse) between the 2 groups (p = .84).
CONCLUSION: Compared with the use of multifilament PET sutures, the use of monofilament PP sutures in transvaginal USLS may reduce suture-related complications without increasing surgical failure rates.
DESIGN: Retrospective cohort study.
SETTING: Single teaching hospital.
PATIENTS: Total of 229 patients who underwent transvaginal USLS and completed a 1-year follow-up.
INTERVENTIONS: Use of PET and PP sutures for transvaginal USLS procedures.
MEASUREMENTS AND MAIN RESULTS: PP sutures were used in 149 patients, and PET sutures were used in 80 patients. The suture-related complication rates, including granulation tissue and suture erosion at the vaginal apex, were significantly higher in the PET suture group than in the PP suture group (46.3% vs 20.1%, p <.01). However, there was no significant difference in the rates of surgical failure (defined as the presence of vaginal bulging symptoms, apical descent ≥ half of the total vaginal length, anterior or posterior vaginal wall descent beyond the hymen, or retreatment for prolapse) between the 2 groups (p = .84).
CONCLUSION: Compared with the use of multifilament PET sutures, the use of monofilament PP sutures in transvaginal USLS may reduce suture-related complications without increasing surgical failure rates.