MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5301/tj.5000305

Медицинская библиотека · Tumori · 2015

Three-dimensional ultrasound-based target volume delineation and consequent dose calculation in prostate cancer patients with bilateral hip replacement: a report of 4 cases.

Arcadipane Francesca, Fiandra Christian, Franco Pierfrancesco, Munoz Fernando, Irgolini Paolo, Trino Elisabetta, Levis Mario, Guarneri Alessia, Ricardi Umberto

Клинический случайСтатьяПеревод пока не подготовлен

Аннотация

AIM: To investigate the role of 3D ultrasound (3D-US) in target volume delineation in prostate cancer radiotherapy.

METHODS

Four patients with intermediate risk prostate cancer and metal artifacts on planning computed tomography (CT) due to previous bilateral hip replacement underwent 3D-US with the Clarity platform (Clarity System, Elekta, Stockholm, Sweden) to allow for image-guided procedures. Ultrasound and CT images were coregistered to allow for better delineation of the prostate gland and organs at risk (OAR). Electron density override (EDO) and standard electron density (EDS) methods were compared for appropriate dose calculation.

RESULTS

3D-US and planning CT minimized image artifacts, providing better evidence of patient anatomy, particularly regarding soft tissue visualization. Prostate gland and seminal vesicles were better delineated, particularly in the posterior aspect. Anterior rectal wall and bladder neck were more visible. No difference was found in terms of average planning target volume dose, D15%, or D25% for rectum or D15%, D25%, or D35% of bladder between EDO and EDS.

CONCLUSIONS

3D-US proved to be a viable tool for target volume and OAR visualization in patients with prostate cancer with hip prostheses.

Для цитирования: Arcadipane Francesca, Fiandra Christian, Franco Pierfrancesco, Munoz Fernando, Irgolini Paolo, Trino Elisabetta, Levis Mario, Guarneri Alessia, Ricardi Umberto. Three-dimensional ultrasound-based target volume delineation and consequent dose calculation in prostate cancer patients with bilateral hip replacement: a report of 4 cases.. Tumori. 2015. DOI: 10.5301/tj.5000305.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.