Journal of periodontology · 2012
The effect of an 810-nm diode laser on postoperative pain and tissue response after modified Widman flap surgery: a pilot study in humans.
Сравнительное исследованиеСтатьяРандомизированное исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Sanz-Moliner Javier D, Nart José, Cohen Robert E, Ciancio Sebastian G
Аннотация
BACKGROUND: The purpose of this single-masked pilot clinical study is to compare the tissue response and postoperative pain after the use of a diode laser (810 nm) (DL) as an adjunct to modified Widman flap (MWF) surgery to that of MWF alone.
METHODS: Thirteen patients with generalized severe chronic periodontitis completed the study. Control sites were randomly selected to receive an MWF and the contralateral test sites an MWF in conjunction with a DL. The study tooth/site was treated plus any additional teeth in the quadrant in which the site was located, if needed. Randomization was done using a coin flip. The DL was used to de-epithelialize the inner part of the periodontal flap and photo-biostimulate the surgical area. Pain scale assessment (PS), pain medication consumption (PM), tissue edema (TE), and tissue color (TC) were evaluated 1 week after surgery.
RESULTS: Statistically significant differences were seen for TE (P = 0.041), PM (P <0.001), and PS (P <0.001) favoring test sites. TC did not show a statistically significant difference (P = 0.9766). Patients rated the first surgical treatment (test or control; random assignment to first treatment) performed as more painful than the second (P <0.002).
CONCLUSION: The use of an 810-nm diode laser provided additional benefits to MWF surgery in terms of less edema and postoperative pain.
METHODS: Thirteen patients with generalized severe chronic periodontitis completed the study. Control sites were randomly selected to receive an MWF and the contralateral test sites an MWF in conjunction with a DL. The study tooth/site was treated plus any additional teeth in the quadrant in which the site was located, if needed. Randomization was done using a coin flip. The DL was used to de-epithelialize the inner part of the periodontal flap and photo-biostimulate the surgical area. Pain scale assessment (PS), pain medication consumption (PM), tissue edema (TE), and tissue color (TC) were evaluated 1 week after surgery.
RESULTS: Statistically significant differences were seen for TE (P = 0.041), PM (P <0.001), and PS (P <0.001) favoring test sites. TC did not show a statistically significant difference (P = 0.9766). Patients rated the first surgical treatment (test or control; random assignment to first treatment) performed as more painful than the second (P <0.002).
CONCLUSION: The use of an 810-nm diode laser provided additional benefits to MWF surgery in terms of less edema and postoperative pain.
Предметные рубрики MeSH
Analgesics, Non-NarcoticChronic PeriodontitisColorCombined Modality TherapyEdemaFemaleHumansIbuprofenLasers, SemiconductorLow-Level Light TherapyMaleMiddle AgedPain MeasurementPostoperative PainPeriodontal PocketPilot ProjectsPostoperative ComplicationsSingle-Blind MethodSurgical FlapsTreatment OutcomeWound Healing