MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/0301-4738.37593

Медицинская библиотека · Indian journal of ophthalmology · 2008

Helical computed tomographic dacryocystography and its role in the diagnosis and management of lacrimal drainage system blocks and medial canthal masses.

Udhay Priti, Noronha Olma Veena, Mohan Ravindra E

СтатьяПеревод пока не подготовлен

Аннотация

AIM: To study the indications, technique and diagnostic utility of helical computed tomographic dacryocystography (CTDCG).

MATERIALS AND

METHODS

Retrospective analysis of 13 patients who underwent CTDCG with subsequent surgical intervention, during the period January 2003 to December 2005, was done. Axial plain computed tomography (CT) scan was performed, followed by administration of water-soluble contrast in the conjunctival cul de sac or by cannulation of the lacrimal passages. Thin-slice helical CT with two-dimensional (2D) and three-dimensional (3D) coronal and sagittal reformation was done.

RESULTS

Four patients were males and 9 were females. Age range was 5 to 62 years. Seven patients presented with watering and 6 patients with a medial canthal mass. Three patients had history of trauma. CTDCG was performed by instillation technique in 10 patients and by cannulation in 3 patients. CTDCG showed mass lesion displacing the sac in 5 cases, nasolacrimal duct obstruction in 6 cases and mucocele in 2 cases. Based on the findings on CTDCG, 5 patients underwent mass excision, 7 underwent dacryocystorhinostomy and 1 patient underwent primary silicone tube intubation.

CONCLUSION

Helical CTDCG is a safe and useful diagnostic tool for the lacrimal surgeon. Instillation technique is a physiological and convenient method, and cannulation is needed only in cases where adequate visualization is not achieved.

Для цитирования: Udhay Priti, Noronha Olma Veena, Mohan Ravindra E. Helical computed tomographic dacryocystography and its role in the diagnosis and management of lacrimal drainage system blocks and medial canthal masses.. Indian journal of ophthalmology. 2008. DOI: 10.4103/0301-4738.37593.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.