MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12936-018-2390-6

Медицинская библиотека · Malaria journal · 2018

Comparison of glucose-6 phosphate dehydrogenase status by fluorescent spot test and rapid diagnostic test in Lao PDR and Cambodia.

Henriques Gisela, Phommasone Koukeo, Tripura Rupam, Peto Thomas J, Raut Shristi, Snethlage Coco, Sambo Im, Sanann Nou, Nguon Chea, Adhikari Bipin, Pongvongsa Tiengkham, Imwong Mallika, von Seidlein Lorenz, Day Nicholas P, White Nicholas J, Dondorp Arjen M, Newton Paul, Ley Benedikt, Mayxay Mayfong

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Glucose-6-phosphate dehydrogenase (G6PD) deficiency is the most common enzymopathy worldwide. Primaquine is the only licensed drug that effectively removes Plasmodium vivax hypnozoites from the human host and prevents relapse. While well tolerated by most recipients, primaquine can cause haemolysis in G6PD deficient individuals and is, therefore, underused. Rapid diagnostic tests (RDTs) could permit ascertainment of G6PD status outside of laboratory settings and hence safe treatment in remote areas. The performance of the fluorescent spot test (Trinity, Ireland; FST) and a G6PD RDT (Carestart, USA) against spectrophotometry were assessed.

METHODS

Participants were enrolled during cross-sectional surveys in Laos and by purposive sampling in Cambodia. FST and RDT were performed during village surveys and 3 mL of venous blood was collected for subsequent G6PD measurement by spectrophotometry.

RESULTS

A total of 757 participants were enrolled in Laos and 505 in Cambodia. FST and RDT performed best at 30% cut-off activity and performed significantly better in Laos than in Cambodia. When defining intermediate results as G6PD deficient, the FST had a sensitivity of 100% (95%CI 90-100) and specificity of 90% (95%CI 87.7-92.2) in Laos and sensitivity of 98% (94.1-99.6) and specificity of 71% (95%CI 66-76) in Cambodia (p < 0.001). The RDT had sensitivity and specificity of 100% (95%CI 90-100) and 99% (95%CI 97-99) in Laos and sensitivity and specificity of 91% (86-96) and 93% (90-95) in Cambodia (p < 0.001). The RDT performed significantly better (all p < 0.05) than the FST when intermediate FST results were defined as G6PD deficient.

CONCLUSION

The interpretation of RDT results requires some training but is a good alternative to the FST. Trial registration clinicaltrials.gov; NCT01872702; 06/27/2013; https://clinicaltrials.gov/ct2/show/NCT01872702.

Для цитирования: Henriques Gisela, Phommasone Koukeo, Tripura Rupam, Peto Thomas J, Raut Shristi, Snethlage Coco, Sambo Im, Sanann Nou, Nguon Chea, Adhikari Bipin, Pongvongsa Tiengkham, Imwong Mallika, von Seidlein Lorenz, Day Nicholas P, White Nicholas J, Dondorp Arjen M, Newton Paul, Ley Benedikt, Mayxay Mayfong. Comparison of glucose-6 phosphate dehydrogenase status by fluorescent spot test and rapid diagnostic test in Lao PDR and Cambodia.. Malaria journal. 2018. DOI: 10.1186/s12936-018-2390-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.