MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ijrobp.2023.10.015

Медицинская библиотека · International journal of radiation oncology, biology, physics · 2023

Impact of Interfractional Bladder and Trigone Displacement and Deformation on Radiation Exposure and Subsequent Acute Genitourinary Toxicity: A Post Hoc Analysis of Patients Treated with Magnetic Resonance Imaging-Guided Prostate Stereotactic Body Radiation Therapy in a Phase 3 Randomized Trial.

Neilsen Beth K, Ma Ting Martin, Akingbemi Wisdom O, Neylon Jack, Casado Maria C, Sharma Sahil, Sheng Ke, Ruan Dan, Low Daniel A, Yang Yingli, Valle Luca F, Steinberg Michael L, Lamb James M, Cao Minsong, Kishan Amar U

Клиническое исследование III фазыРандомизированное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Emerging data suggest that trigone dosimetry may be more associated with poststereotactic body radiation therapy (SBRT) urinary toxicity than whole bladder dosimetry. We quantify the dosimetric effect of interfractional displacement and deformation of the whole bladder and trigone during prostate SBRT using on-board, pretreatment 0.35T magnetic resonance images (MRI).

METHODS AND MATERIALS: Seventy-seven patients treated with MRI-guided prostate SBRT (40 Gy/5 fractions) on the MRI arm of a phase 3 single-center randomized trial were included. Bladder and trigone structures were contoured on images obtained from a 0.35T simulation MRI and 5 on-board pretreatment MRIs. Dice similarity coefficient (DSC) scores and changes in volume between simulation and daily treatments were calculated. Dosimetric parameters including Dmax, D0.03 cc, Dmean, V40 Gy, V39 Gy, V38 Gy, and V20 Gy for the bladder and trigone for the simulation and daily treatments were collected. Both physician-scored (Common Terminology Criteria for Adverse Events, version 4.03 scale) as well as patient-reported (International Prostate Symptom Scores and the Expanded Prostate Cancer Index Composite-26 scores) acute genitourinary (GU) toxicity outcomes were collected and analyzed.

RESULTS

The average treatment bladder volume was about 30% smaller than the simulation bladder volume; however, the trigone volume remained fairly consistent despite being positively correlated with total bladder volume. Overall, the trigone accounted for <2% of the bladder volume. Median DSC for the bladder was 0.79, whereas the median DSC of the trigone was only 0.33. No statistically significant associations between our selected bladder and trigonal dosimetric parameters and grade ≥2 GU toxicity were identified, although numerically, patients with GU toxicity (grade ≥2) had higher intermediate doses to the bladder (V20 Gy and Dmean) and larger volumes exposed to higher doses in the trigone (V40 Gy, V39 Gy, and V38 Gy).

CONCLUSIONS

The trigone exhibits little volume change, but considerable interfractional displacement/deformation. As a result, the relative volume of the trigone receiving high doses during prostate SBRT varies substantially between fractions, which could influence GU toxicity and may not be predicted by radiation planning dosimetry.

Для цитирования: Neilsen Beth K, Ma Ting Martin, Akingbemi Wisdom O, Neylon Jack, Casado Maria C, Sharma Sahil, Sheng Ke, Ruan Dan, Low Daniel A, Yang Yingli, Valle Luca F, Steinberg Michael L, Lamb James M, Cao Minsong, Kishan Amar U. Impact of Interfractional Bladder and Trigone Displacement and Deformation on Radiation Exposure and Subsequent Acute Genitourinary Toxicity: A Post Hoc Analysis of Patients Treated with Magnetic Resonance Imaging-Guided Prostate Stereotactic Body Radiation Therapy in a Phase 3 Randomized Trial.. International journal of radiation oncology, biology, physics. 2023. DOI: 10.1016/j.ijrobp.2023.10.015.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.