MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/00005392-199909010-00084

Медицинская библиотека · The Journal of urology · 1999

Antibiotic hydrogel coated Foley catheters for prevention of urinary tract infection in a rabbit model.

Pugach J L, DiTizio V, Mittelman M W, Bruce A W, DiCosmo F, Khoury A E

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

PURPOSE: We developed an antibiotic liposome (ciprofloxacin liposome) containing hydrogel for external coating of silicone Foley catheters and evaluated its efficacy in a rabbit model. Our goal was to create a catheter that would hinder the development of catheter associated nosocomial urinary tract infections.

MATERIALS AND

METHODS

We inserted either an untreated, liposomal hydrogel coated or a liposome hydrogel with ciprofloxacin coated 10F silicone Foley catheter into New Zealand White rabbits. We challenged the system with 5x10(6) virulent Escherichia coli at the urethral meatus twice daily for 3 days. Urine cultures were evaluated twice daily for 7 days. When urine cultures became positive, the rabbits were sacrificed and urine, urethral catheter and urethral tissue were cultured.

RESULTS

The time to bacteriuria detection in 50% of the specimens was double for hydrogel with ciprofloxacin coated catheters versus untreated and hydrogel coated catheters. A significant (p = 0.04) improvement in average time to positive urine culture from 3.5 to 5.3 days and a 30% decrease in the bacteriuria rate for hydrogel with ciprofloxacin coated catheters were noted compared to untreated catheters.

CONCLUSIONS

A significant benefit was realized by coating the extraluminal catheter surface with a ciprofloxacin liposome impregnated hydrogel. We believe this procedure will provide a significant clinical advantage, while reducing health care costs substantially.

Для цитирования: Pugach J L, DiTizio V, Mittelman M W, Bruce A W, DiCosmo F, Khoury A E. Antibiotic hydrogel coated Foley catheters for prevention of urinary tract infection in a rabbit model.. The Journal of urology. 1999. DOI: 10.1097/00005392-199909010-00084.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.