Cardiac impact of R-wave triggered irreversible electroporation therapy.

Kostrzewa Michael, Tueluemen Erol, Rudic Boris, Rathmann Nils, Akin Ibrahim, Henzler Thomas, Liebe Volker, Schoenberg Stefan O, Borggrefe Martin, Diehl Steffen J

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Irreversible electroporation (IRE) is a novel tumor ablative therapy technique, using electric fields to induce apoptosis in target tissues. Whether these electric pulses of high field strength can cause cardiac damage and/or ablation-induced arrhythmias is unclear.

OBJECTIVE

The purpose of this study was to systematically evaluate the safety of electrocardiogram (ECG)-gated IRE with regard to cardiac side effects.

METHODS

In all patients, 12-lead ECG and signal-averaged ECG (SAECG) recordings were performed before and after IRE and 24-hour Holter recording on the day of the IRE procedure. Venous blood samples (N-terminal pro-brain-type natriuretic peptide [NT-proBNP], high-sensitive troponin I [hsTnI]) were obtained before and 4 and 16 hours after the procedure. Patients with abnormal findings were reevaluated after 3 months.

RESULTS

In total, 26 patients with an oncologic indication for IRE (11 females, mean age 62.9 years) were prospectively enrolled. Nine patients (34.6%) showed an increase in hsTnI and 21 patients (80.8%) an increase in NT-proBNP after ablation. Fifteen patients (57%) developed arrhythmias related to the procedure. One patient, in whom hsTnI and NT-proBNP had increased, developed multiple, nonsustained ventricular tachycardia events. In another patient, atrial fibrillation was triggered twice in 2 separate procedures. Twelve patients had clinically benign arrhythmias. SAECG was negative in all patients.

CONCLUSION

Subclinical myocardial injury and nonfatal cardiac arrhythmias can occur in the context of IRE treatment. Although no sustained cardiac injuries could be found at 3-month follow-up, we propose implementation of a cardiac safety algorithm consisting of cardiac biomarkers and ECG monitoring when IRE is conducted.

Для цитирования: Kostrzewa Michael, Tueluemen Erol, Rudic Boris, Rathmann Nils, Akin Ibrahim, Henzler Thomas, Liebe Volker, Schoenberg Stefan O, Borggrefe Martin, Diehl Steffen J. Cardiac impact of R-wave triggered irreversible electroporation therapy.. Heart rhythm. 2018. DOI: 10.1016/j.hrthm.2018.07.013.