MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jmr.2017.02.012

Медицинская библиотека · Journal of magnetic resonance (San Diego, Calif. : 1997) · 2017

Non-uniformly weighted sampling for faster localized two-dimensional correlated spectroscopy of the brain in vivo.

Verma Gaurav, Chawla Sanjeev, Nagarajan Rajakumar, Iqbal Zohaib, Albert Thomas M, Poptani Harish

СтатьяПеревод пока не подготовлен

Аннотация

Two-dimensional localized correlated spectroscopy (2D L-COSY) offers greater spectral dispersion than conventional one-dimensional (1D) MRS techniques, yet long acquisition times and limited post-processing support have slowed its clinical adoption. Improving acquisition efficiency and developing versatile post-processing techniques can bolster the clinical viability of 2D MRS. The purpose of this study was to implement a non-uniformly weighted sampling (NUWS) scheme for faster acquisition of 2D-MRS. A NUWS 2D L-COSY sequence was developed for 7T whole-body MRI. A phantom containing metabolites commonly observed in the brain at physiological concentrations was scanned ten times with both the NUWS scheme of 12:48 duration and a 17:04 constant eight-average sequence using a 32-channel head coil. 2D L-COSY spectra were also acquired from the occipital lobe of four healthy volunteers using both the proposed NUWS and the conventional uniformly-averaged L-COSY sequence. The NUWS 2D L-COSY sequence facilitated 25% shorter acquisition time while maintaining comparable SNR in humans (+0.3%) and phantom studies (+6.0%) compared to uniform averaging. NUWS schemes successfully demonstrated improved efficiency of L-COSY, by facilitating a reduction in scan time without affecting signal quality.

Для цитирования: Verma Gaurav, Chawla Sanjeev, Nagarajan Rajakumar, Iqbal Zohaib, Albert Thomas M, Poptani Harish. Non-uniformly weighted sampling for faster localized two-dimensional correlated spectroscopy of the brain in vivo.. Journal of magnetic resonance (San Diego, Calif. : 1997). 2017. DOI: 10.1016/j.jmr.2017.02.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.