MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/cod.13533

Медицинская библиотека · Contact dermatitis · 2020

Metals in used and unused metalworking fluids: X-ray fluorescence spectrometry as a screening test.

Alinaghi Farzad, Hedberg Yolanda S, Zachariae Claus, Thyssen Jacob P, Johansen Jeanne D

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Exposure to metalworking fluids (MWFs) is a well-known cause of occupational contact dermatitis.

OBJECTIVES

We aimed to (1) determine the amount of nickel, chromium, and cobalt in large samples of used and unused MWFs collected from metalworking plants in Denmark, and (2) evaluate a handheld x-ray fluorescence (XRF) device as a screening instrument for metals in MWFs.

METHODS

A handheld XRF device was used to screen for metals in MWFs. All samples were also analyzed for concentrations of nickel, chromium, and cobalt using graphite furnace atomic absorption spectroscopy (GFAAS).

RESULTS

GFAAS analysis showed that 13 of 80 samples (16.3%) contained >1 mg/kg (ppm) nickel (range: 6.4-17.7 mg/kg), 3 of 80 (3.8%) contained >1 (range: 1.4-3.1) mg/kg chromium, and 1 of 80 (1.3%) contained 1.3 mg/kg cobalt. XRF-screening detected nickel in eight samples (range: 2.5-15.5 mg/kg), but only one sample with 3.0 (±0.5) mg/kg was found subsequently to contain 9.9 (0.02) mg/kg nickel by GFAAS. Although no chromium was found by XRF analysis, cobalt was found in two samples with 6 (±1.5) mg/kg and 5 (±1.5) mg/kg, subsequently found to contain 0.1 (±0.01) mg/kg and 0.08 (±0.01) mg/kg by GFAAS. Similar concentrations of nickel were found in used (N = 6, range: 6.4-17.7 mg/kg) and unused MWFs (N = 7, range: 9.1-17.3 mg/kg).

CONCLUSION

Considerable levels of nickel, chromium, and cobalt were found in some used and unused MWFs indicating that these might represent a source of metal allergy. The XRF device is a poor screening test for these metals in MWFs.

Для цитирования: Alinaghi Farzad, Hedberg Yolanda S, Zachariae Claus, Thyssen Jacob P, Johansen Jeanne D. Metals in used and unused metalworking fluids: X-ray fluorescence spectrometry as a screening test.. Contact dermatitis. 2020. DOI: 10.1111/cod.13533.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.