Vestnik otorinolaringologii · 2022
[Electrically evoked ABR through cochlear implant in children with auditory neuropathy spectrum disorder].
СтатьяНазвание и аннотация: Оригинал на русском
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lalayants M R, Chugunova T I, Bakhshinyan V V, Tavartkiladze G A
Аннотация
OBJECTIVE: To estimate the applicability of electrically evoked auditory brainstem response (eABR) registration for the estimation of neural integrity after cochlear implantation (CI) in children with auditory neuropathy spectrum disorder (ANSD) and to compare the eABR data with patient's hearing performance.
MATERIAL AND METHODS: 4 children, Nucleus (Cochlear) CI users, with ANSD were enrolled in the study. Hearing performance in these children ranged from successful to unsatisfied. eABR were recorded via Eclipse EP25 (Interacoustics). Electrical bipolar stimulation was achieved with Custom Sound EP software (Cochlear).
RESULTS: EABR were registered with the use of different stimulation parameters (pulse width, stimulated electrodes) in 3 patients with satisfactory results of rehabilitation. eABR thresholds corresponded to maximum comfortable levels of patients stimulation MAP. eABR were absent in the patient with poor hearing performance.
CONCLUSIONS: EABR measurements in children with ANSD demonstrated restoration of neuronal conduction in the auditory pathway up to the brainstem after cochlear implantation in 3 patients. eABR results were well correlated with hearing performance. Thereby, the study of eABR applicability for clinical practice will be expanded.
MATERIAL AND METHODS: 4 children, Nucleus (Cochlear) CI users, with ANSD were enrolled in the study. Hearing performance in these children ranged from successful to unsatisfied. eABR were recorded via Eclipse EP25 (Interacoustics). Electrical bipolar stimulation was achieved with Custom Sound EP software (Cochlear).
RESULTS: EABR were registered with the use of different stimulation parameters (pulse width, stimulated electrodes) in 3 patients with satisfactory results of rehabilitation. eABR thresholds corresponded to maximum comfortable levels of patients stimulation MAP. eABR were absent in the patient with poor hearing performance.
CONCLUSIONS: EABR measurements in children with ANSD demonstrated restoration of neuronal conduction in the auditory pathway up to the brainstem after cochlear implantation in 3 patients. eABR results were well correlated with hearing performance. Thereby, the study of eABR applicability for clinical practice will be expanded.