MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12885-022-09213-z

Медицинская библиотека · BMC cancer · 2022

Dosimetric analysis of radiation-induced brainstem necrosis for nasopharyngeal carcinoma treated with IMRT.

Fan Xigang, Huang Yecai, Xu Peng, Min Yanmei, Li Jie, Feng Mei, Xu Guohui, Lang Jinyi

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Radiation-induced brainstem necrosis (RIBN) is a late life-threatening complication that can appear after treatment in patients with nasopharyngeal carcinoma (NPC). However, the relationship between RIBN and radiation dose is not still well-defined.

METHODS

During January 2013 and December 2017, a total of 1063 patients with NPC were treated at Sichuan cancer hospital with IMRT. A total of 479 patients were eligible for dosimetric analysis. Dosimetric parameters of the RIBN, Dmax(the maximum dose), D0.1c (maximum average dose delivered to a 0.1-cc volume), D1cc, D2cc, D3cc, D5cc, D10cc and Dmean (mean does) were evaluated and recorded. ROC curve was used to analyze the area under curve (AUC) and cutoff points. Logistic regression for screening dose-volume parameter and logistic dose response model were used to predict the incidence of brainstem necrosis.

RESULTS

Among the 479 patients with NPC, 6 patients were diagnosed with RIBN, the incidence of RIBN was 1.25% (6/479), and the median time to RIBN after treatment was 28.5 months (range 18-48 months). The dose of the brainstem in patients with RIBN were higher than that in patients without necrosis. ROC curve showed that the area under the curve (AUC) of Dmax was the largest (0.987). Moreover, logistic stepwise regression indicated that Dmax was the most important dose factor. The RIBN incidence at 5% over 5 years (TD5/5) and 50% incidence over 5 years (TD50/5) was 69.59 Gy and76.45 Gy, respectively.

CONCLUSIONS

Brainstem necrosis is associated with high dose irritation. Dmax is the most significant predictive dosimetric factor for RIBN. Dmax of brainstem should be considered as the dose limitation parameter. We suggest that the limitation dose for brainstem was Dmax < 69.59 Gy.

Для цитирования: Fan Xigang, Huang Yecai, Xu Peng, Min Yanmei, Li Jie, Feng Mei, Xu Guohui, Lang Jinyi. Dosimetric analysis of radiation-induced brainstem necrosis for nasopharyngeal carcinoma treated with IMRT.. BMC cancer. 2022. DOI: 10.1186/s12885-022-09213-z.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.