MedElevator Войти в исследования
← Поиск публикаций

DOI 10.5009/gnl15579

Медицинская библиотека · Gut and liver · 2017

Antireflux Metal Stent as a First-Line Metal Stent for Distal Malignant Biliary Obstruction: A Pilot Study.

Hamada Tsuyoshi, Isayama Hiroyuki, Nakai Yousuke, Togawa Osamu, Takahara Naminatsu, Uchino Rie, Mizuno Suguru, Mohri Dai, Yagioka Hiroshi, Kogure Hirofumi, Matsubara Saburo, Yamamoto Natsuyo, Ito Yukiko, Tada Minoru, Koike Kazuhiko

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND/AIMS: In distal malignant biliary obstruction, an antireflux metal stent (ARMS) with a funnel-shaped valve is effective as a reintervention for metal stent occlusion caused by reflux. This study sought to evaluate the feasibility of this ARMS as a first-line metal stent.

METHODS

Patients with nonresectable distal malignant biliary obstruction were identified between April and December 2014 at three Japanese tertiary centers. We retrospectively evaluated recurrent biliary obstruction and adverse events after ARMS placement.

RESULTS

In total, 20 consecutive patients were included. The most common cause of biliary obstruction was pancreatic cancer (75%). Overall, recurrent biliary obstruction was observed in seven patients (35%), with a median time to recurrent biliary obstruction of 246 days (range, 11 to 246 days). Stent occlusion occurred in five patients (25%), the causes of which were sludge and food impaction in three and two patients, respectively. Stent migration occurred in two patients (10%). The rate of adverse events associated with ARMS was 25%: pancreatitis occurred in three patients, cholecystitis in one and liver abscess in one. No patients experienced nonocclusion cholangitis.

CONCLUSIONS

The ARMS as a first-line biliary drainage procedure was feasible. Because the ARMS did not fully prevent stent dysfunction due to reflux, further investigation is warranted.

Для цитирования: Hamada Tsuyoshi, Isayama Hiroyuki, Nakai Yousuke, Togawa Osamu, Takahara Naminatsu, Uchino Rie, Mizuno Suguru, Mohri Dai, Yagioka Hiroshi, Kogure Hirofumi, Matsubara Saburo, Yamamoto Natsuyo, Ito Yukiko, Tada Minoru, Koike Kazuhiko. Antireflux Metal Stent as a First-Line Metal Stent for Distal Malignant Biliary Obstruction: A Pilot Study.. Gut and liver. 2017. DOI: 10.5009/gnl15579.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.