VALIDATION OF A NEW WATER-PERFUSED HIGH-RESOLUTION MANOMETRY SYSTEM.

Mariotto Rogério, Herbella Fernando A M, Andrade Vera Lucia Ângelo, Schlottmann Francisco, Patti Marco G

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Water-perfused high resolution manometry system. High-resolution manometry is more costly but clinically superior to conventional manometry. Water-perfused systems may decrease costs, but it is unclear if they are as reliable as solid-state systems, and reference values are interchangeable.

AIM: To validate normal values for a new water-perfusion high-resolution manometry system.

METHODS

Normative values for a 24-sensors water perfused high-resolution manometry system were validated by studying 225 individuals who underwent high resolution manometry for clinical complaints. Patients were divided in four groups: group 1 - gastroesophageal reflux disease; group 2 - achalasia; group 3 - systemic diseases with possible esophageal manifestation; and group 4 - dysphagia.

RESULTS

In group 1, a hypotonic lower esophageal sphincter was found in 49% of individuals with positive 24 h pH monitoring, and in 28% in pH-negative individuals. In groups 2 and 3, aperistalsis was found in all individuals. In group 4, only one patient (14%) had normal high-resolution manometry.

CONCLUSIONS

The normal values determined for this low-cost water-perfused HRM system with unique peristaltic pump and helicoidal sensor distribution are discriminatory of most abnormalities of esophageal motility seen in clinical practice.

Для цитирования: Mariotto Rogério, Herbella Fernando A M, Andrade Vera Lucia Ângelo, Schlottmann Francisco, Patti Marco G. VALIDATION OF A NEW WATER-PERFUSED HIGH-RESOLUTION MANOMETRY SYSTEM.. Arquivos brasileiros de cirurgia digestiva : ABCD = Brazilian archives of digestive surgery. 2021. DOI: 10.1590/0102-672020200004e1557.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.