DOI 10.1016/j.crad.2024.03.010
Ultrasound accuracy for brachial plexus pathology.
Аннотация
AIM: To determine (a) the accuracy of ultrasound in detecting brachial plexus pathology and (b) outline the advantages and limitations of ultrasound compared to MRI for imaging the brachial plexus.
MATERIAL AND
METHODS
cases with clinically suspected brachial plexus pathology were evaluated first by ultrasound, followed by MRI. Patients with prior brachial plexus imaging were excluded. The final diagnosis was based on a combination of ultrasound, MRI, clinical follow-up, and surgical findings. The accuracy of the ultrasound was assessed by comparing the ultrasound and the final diagnoses. The mean clinical follow-up time following ultrasound was 1.8 ± 1.4 years.
RESULTS
Ninety-two (64%) of the 143 cases had normal brachial plexus ultrasound and MRI examinations. Fifty-one (36%) of 143 cases had brachial plexus pathology on MRI, comprising post-radiation fibrosis (n=25, 49%), nerve sheath tumor (n=11, 21%), traumatic injury (n=7, 14%), inflammatory polyneuropathy (n=4, 8%), malignant infiltration (n=2, 4%), desmoid fibromatosis (n=1,2%), and neuralgic amyotrophy (n=1, 2%). Overall diagnostic accuracy of ultrasound for brachial plexus pathology was 98% (140/143), with three discordant cases (neuralgic amyotrophy n=1, inflammatory neuropathy n=1, postradiation fibrosis n=1) regarded as normal on ultrasound assessment. Sensitivity, specificity, and positive and negative predictive value of ultrasound for identifying brachial plexus pathology were 94%, 100%, 100%, and 97%, respectively.
CONCLUSION
Ultrasound identifies brachial plexus pathology with high accuracy and specificity, showing comparable diagnostic efficacy to MRI. Ultrasound can serve as an effective first-line imaging investigation for suspected brachial plexus pathology.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.