Minerva gastroenterology · 2022
Use of catheter-based cholangioscopy in the diagnosis of indeterminate stenosis: a multicenter experience.
СтатьяМногоцентровое исследованиеОбзорНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Pallio Socrate, Sinagra Emanuele, Santagati Alessio, D'Amore Fabio, Pompei Giancarlo, Conoscenti Giuseppe, Romeo Fabio, Borina Eleonora, Melita Giuseppinella, Rossi Francesca, Maida Marcello, Alloro Rita, Tarantino Ilaria, Raimondo Dario
Аннотация
BACKGROUND: Direct bile ducts visualization through cholangioscopy has gained popularity due to its better diagnostic accuracy than a standard ERCP in indeterminate biliary stricture.
METHODS: We aimed to review our catheter-based cholangioscopy interventions in patients with indeterminate biliary stenosis, using the SpyGlass Direct Visualization System (SDVS) and summarize our experience in terms of procedures and results. We collected 25 consecutive patients with indeterminate biliary stricture over 3 years.
RESULTS: The overall procedural success in our cohort amounted to 96% (24/25). If we focus on the diagnostic procedures, the ability to merely visualize the region of interest/lesion and perform biopsy of the lesion was possible in 96% (24/25) In our cohort localization in the common bile duct (P=0.03; 95% CI: 0.27-0.96) was found as positive determining factor for diagnosis. Sensitivity, specificity and accuracy for visual diagnosis by SDVS in our cohort were 100, 83.3 and 96%, respectively. The use of biopsy or obtaining a histological diagnosis to assist in identifying patients with malignant stenosis, to exclude malignancy and to correctly classify diagnosed patients resulted in a sensitivity of 100%, a specificity of 73% with an overall accuracy of 94.4%. Only a mild adverse event (cholangitis, treated conservatively) occurred.
CONCLUSIONS: Today, the SDVS should be considered essential in diagnosing indeterminate biliary strictures, since the procedure is associated with high procedural success in terms of diagnostic accuracy, alters clinical outcome in over 80% of considered insolvable cases, with an acceptable safety profile.
METHODS: We aimed to review our catheter-based cholangioscopy interventions in patients with indeterminate biliary stenosis, using the SpyGlass Direct Visualization System (SDVS) and summarize our experience in terms of procedures and results. We collected 25 consecutive patients with indeterminate biliary stricture over 3 years.
RESULTS: The overall procedural success in our cohort amounted to 96% (24/25). If we focus on the diagnostic procedures, the ability to merely visualize the region of interest/lesion and perform biopsy of the lesion was possible in 96% (24/25) In our cohort localization in the common bile duct (P=0.03; 95% CI: 0.27-0.96) was found as positive determining factor for diagnosis. Sensitivity, specificity and accuracy for visual diagnosis by SDVS in our cohort were 100, 83.3 and 96%, respectively. The use of biopsy or obtaining a histological diagnosis to assist in identifying patients with malignant stenosis, to exclude malignancy and to correctly classify diagnosed patients resulted in a sensitivity of 100%, a specificity of 73% with an overall accuracy of 94.4%. Only a mild adverse event (cholangitis, treated conservatively) occurred.
CONCLUSIONS: Today, the SDVS should be considered essential in diagnosing indeterminate biliary strictures, since the procedure is associated with high procedural success in terms of diagnostic accuracy, alters clinical outcome in over 80% of considered insolvable cases, with an acceptable safety profile.