MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1109/tnsre.2018.2829183

Медицинская библиотека · IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2018

The S-Finger: A Synergetic Externally Powered Digit With Tactile Sensing and Feedback.

Imbinto I, Montagnani F, Bacchereti M, Cipriani C, Davalli A, Sacchetti R, Gruppioni E, Castellano S, Controzzi M

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Partial hand amputation is by far the most common type of amputation worldwide. Nevertheless, regardless of their potential clinical and socioeconomic impact, battery-powered partial hand prostheses, namely, powered digits, have modestly progressed so far, and very few clinical solutions are available today. Here, we present a mechanical architecture, an alternative to state-of-the-art solutions, which exploits a high efficiency, non-back drivable mechanical transmission based on a face-gear pair and a miniaturized clutch. We took inspiration from the synergetic prehension approach proposed by Childress for whole hand amputation. The finger was equipped with a myoelectric controller and a tactile sensor able to provide users with discrete event sensory feedback. Measured speed (90°/s) and force (6.5 N) of the newly dubbed S-Finger proved comparable with those of clinically available prostheses. The design demonstrated to be compact and rugged enough to undergo a clinical viability test with two partial hand amputees, fitted with custom three-fingered research prostheses using the S-Finger. The subjects successfully completed several dexterity tests and gave relevant feedback for the development of a second-generation device. These results contribute to the increasing research endeavors in the field of partial hand amputation.

Для цитирования: Imbinto I, Montagnani F, Bacchereti M, Cipriani C, Davalli A, Sacchetti R, Gruppioni E, Castellano S, Controzzi M. The S-Finger: A Synergetic Externally Powered Digit With Tactile Sensing and Feedback.. IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society. 2018. DOI: 10.1109/tnsre.2018.2829183.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.