MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1088/1361-6560/acec2b

Медицинская библиотека · Physics in medicine and biology · 2023

Microdosimetric assessment about proton spread-out Bragg peak at different depths based on the normal human mesh-type cell population model.

Kong Xianghui, Wang Yidi, Huang Jiachen, Zhang Wenyue, Du Chuansheng, Yin Yuchen, Xue Huiyuan, Gao Han, Liu Kun, Wu Tao, Sun Liang

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

Objective.In clinical proton therapy, the spread-out Bragg peak (SOBP) is commonly used to fit the target shape. Dose depositions at microscopic sites vary, even with a consistent absorbed dose (D) in SOBP. In the present study, monolayer mesh-type cell population models were developed for microdosimetric assessment at different SOBP depths.Approach.Normal human bronchial epithelial (BEAS-2B) and hepatocytes (L-O2) mesh-type cell models were constructed based on fluorescence tomography images of normal human cells. Particle transport simulation in cell populations was performed coupled with Monte Carlo software PHITS. The relationship between microdosimetry and macrodosimetry of SOBP at different depths was described by analyzing the microdosimetric indicators such as specific energyz,specific energy distributionfz,D,and relative standard deviationσz/z¯within cells. Additionally, the microdosimetric distributions characteristics and their contributing factors were also discussed.Main results.The microscopic dose distribution is strongly influenced by cellular size, shape, and material. The mean specific energyz¯of nucleus and cytoplasm in the cell population is greater than the overall absorbed dose of the cell population model (Dp), with a maximumz¯/Dpof 1.1. The cellular dose distribution is different between the BEAS-2B mesh-type model and its concentric ellipsoid geometry-type model, which difference inz¯is about 10.3% for the nucleus and about 7.5% for the cytoplasm with the SOBP depth of 15 cm. WhenD= 2 Gy, the maximumzof L-O2 nucleus reaches 2.8 Gy andσz/z¯is 5.1% at the mid-depth SOBP (16-18 cm); while the maximumzof the BEAS-2B nucleus reaches 2.2 Gy with only 2.7% ofσz/z¯.Significance.The significant variation of microdosimetric distributions of SOBP different depths indicates the necessity to use mesh-type cell population models, which have the potential to be compared with biological results and build the bio-physical model.

Для цитирования: Kong Xianghui, Wang Yidi, Huang Jiachen, Zhang Wenyue, Du Chuansheng, Yin Yuchen, Xue Huiyuan, Gao Han, Liu Kun, Wu Tao, Sun Liang. Microdosimetric assessment about proton spread-out Bragg peak at different depths based on the normal human mesh-type cell population model.. Physics in medicine and biology. 2023. DOI: 10.1088/1361-6560/acec2b.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.