m+Medelevator.RU
← Поиск публикаций
Physics in medicine and biology · 2026

Skin dosimetry in megavoltage radiotherapy using hydrogenated amorphous silicon on a tissue-equivalent flexible substrate.

СтатьяНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Bashiri Aishah, Anderson Cameron, Posar Jessie, Pavitt Shane, Dookie Yashiv, McNamara Joanne, Sandhu Rabia, Aziz Saba, Calcagnile Lucio, Calvo Daniela, Caputo Domenico, Caricato Anna Paola, Catalano Roberto, Cazzanelli Massimo, Cirio Roberto, Cirrone Giuseppe Antonio Pablo, Cittadini Federico, Croci Tommaso, Cuttone Giacomo, de Cesare Gianpiero, de Remigis Paolo, Dunand Sylvain, Fabi Michele, Frontini Luca, Grimani Catia, Guarrera Mariacristina, Hasnaoui Hamza, Insero Giacomo, Ionica Maria, Kanxheri Keida, Konstantinou Georgios, Lenta Francesca, Liberali Valentino, Barraud Loris, Lovecchio Nicola, Ponzecchi Marta, Maruccio Giuseppe, Martino Maurizio, Mazza Giovanni, Menichelli Mauro, Monteduro Anna Grazia, Morozzi Arianna, Nascetti Augusto, Pallotta Stefania, Passeri Daniele, Pedio Maddalena, Petringa Giada, Peverini Francesca, Placidi Pisana, Polo Matteo, Quaranta Alberto, Quarta Gianluca, Rizzato Silvia, Sabbatini Federico, Servoli Leonello, Stabile Alberto, Talamonti Cinzia, Tosti Luca, Mora Monica Setia Vasquez, Verdini Alberto, Villani Mattia, Wheadon Richard James, Wyrsch Nicolas, Petasecca Marco

Аннотация

Acute skin toxicity after radiation treatments highlights the need for improved dose monitoring and measurement, as the treatment planning system does not accurately estimate skin dose. Wearable radiation detectors may be the solution for mostin vivodosimetry needs, but they require innovative materials. The purpose of this work is to overcome the challenges that limit accurate skin dosimetry by exploring the use of hydrogenated amorphous silicon (a-Si:H) fabricated on a flexible polyimide substrate for direct radiation detection. The a-Si:H detector was fabricated on a 125μm polyimide substrate with a thickness of 3.6-10μm. The detector's response to the build-up region of the percentage depth dose (PDD) of the MV photon beam was compared to Geant4 radiation transport simulations and benchmarked to Attix ionization chamber measurements. Angular dependency and surface field factors at the phantom surface were compared to Attix IC. The PDD measurement is within 2% of Geant4's simulation and the Attix chamber's response from 150m to 25 mm in a plastic water phantom. All samples showed linear dose responses with 0.37% reproducibility. The a-Si:H device matches the Attix chamber for surface field factor measurements (6-10 MV photon beams, for 5 to 25 cm field sizes). The angular dependence (-60° to +60°) compared to the Attix IC confirms the sensor's WED of 150 ± 5µm. This study demonstrates that a-Si:H sensors on flexible plastic substrates have a potential for accurate surface dose measurements and agree with reference detectors. This thin, flexible detector provides real time measurements and is stable under high radiation doses. The possibility to assemble with ease an array of a-Si:H pixels over large areas with different sizes and shapes, makes this technology attractive forin vivodosimetry.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты