MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2319/041320-295.1

Медицинская библиотека · The Angle orthodontist · 2021

Three-dimensional cone-beam computed tomography comparison of shorty and standard Class II Carriere Motion appliance.

Wilson Brian, Konstantoni Nikoleta, Kim Ki Beom, Foley Patrick, Ueno Hiroshi

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To compare treatment effects of the standard and shorty Class II Carriere Motion appliances (CMAs) on adolescent patients.

MATERIALS AND

METHODS

Fifty adolescents with Class II malocclusion formed group 1, who were treated with shorty CMA (n = 25, 12.66 ± 1.05 years), and age- and sex-matched group 2, who were treated with standard CMA (n = 25, 12.73 ± 1.07 years). Treatment effects were analyzed by tracing with Invivo software to compare pretreatment (T1) cone-beam computed tomography (CBCT) images with post-CMA (T2) CBCT images. A total of 23 measurements were compared within and between groups.

RESULTS

In groups 1 and 2, maxillary first molars showed significant distal movement from T1 to T2 (1.83 ± 2.11 mm and 2.14 ± 1.34 mm, respectively), with distal tipping and rotation in group 1 (6.52° ± 3.99° and 3.15° ± 7.52°, respectively) but only distal tipping (7.03° ± 3.45°) in group 2. Similarly, in both groups, the maxillary first premolars experienced significant distal movement with distal tipping but no significant rotation. In group 1, maxillary canines did not undergo significant distal movement. In both groups 1 and 2, mandibular first molars experienced significant mesial movement (1.85 ± 1.88 mm and 2.44 ± 2.02 mm, respectively). Group 1 showed statistically significantly less reduction in overjet and less canine distal movement with less distal tipping than group 2 (α < .05).

CONCLUSIONS

The shorty CMA achieved Class II correction similarly to the standard CMA, with less change in overjet and distal tipping movement of the maxillary canines.

Для цитирования: Wilson Brian, Konstantoni Nikoleta, Kim Ki Beom, Foley Patrick, Ueno Hiroshi. Three-dimensional cone-beam computed tomography comparison of shorty and standard Class II Carriere Motion appliance.. The Angle orthodontist. 2021. DOI: 10.2319/041320-295.1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.