MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.brachy.2023.03.003

Медицинская библиотека · Brachytherapy · 2023

Radiobiological evaluation of the stepping-source effect in single-fraction monotherapy high-dose-rate prostate brachytherapy.

Tien Christopher J, Chen Zhe

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

The continued reliance upon the traditional biologically effective dose (BEDT) formalism of BEDT=nd(1+d/(α/β)) may be one possible contributor to the poor clinical outcomes observed with single-fraction 19-20 Gy prescriptions in prostate high-dose-rate (HDR) brachytherapy because BEDT does not consider intrafraction sublethal damage repair (iSLDR). This, along with low α/β and repair half-times comparable to delivery time, could reduce the biological effect predicted using BEDT.

METHODS AND MATERIALS: BED was recalculated with a model accounting for iSLDR, using time-averaged uniform dose rate (BEDg1) patterns and time-variable dose rate (BEDgss) patterns inherent to stepping-source delivery. An assortment of two-pulse delivery sequences assuming 19 Gy in 972 s was analyzed. Calculations were repeated for 17470 and 61050 U to investigate source strength dependence.

RESULTS

BEDg1 and BEDgss was/were lower than BEDT by 16.9% and 11.1%-21.1%, respectively, for 40700 U. For 17470 U, BEDg1 and BEDgss was/were lower than BEDT by 32.5% and 21.5%-37.1%, respectively. For 61050 U, BEDg1 and BEDgss was/were lower than BEDT by 11.9% and 7.8%-15.3%, respectively. BEDgss was most dependent on pulse spacing with milder dependence on pulse onset time. BEDg1 served as a lower bound approximation of BEDgss for fast effective delivery time.

CONCLUSIONS

Even for points with the same calculated dose, the biological dose was significantly reduced by iSLDR (as much as 37.1%). While BEDgss explicitly addressed the temporally-variable dose rate inherent to a stepping-source delivery, calculations were cumbersome. Under certain conditions, BEDg1 may serve as an approachable method to quickly assess "worst-case scenario" BED.

Для цитирования: Tien Christopher J, Chen Zhe. Radiobiological evaluation of the stepping-source effect in single-fraction monotherapy high-dose-rate prostate brachytherapy.. Brachytherapy. 2023. DOI: 10.1016/j.brachy.2023.03.003.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.