MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s1056-8727(01)00168-4

Медицинская библиотека · Journal of diabetes and its complications · 2001

A comparison of insulin lispro and buffered regular human insulin administered via continuous subcutaneous insulin infusion pump.

Raskin P, Holcombe J H, Tamborlane W V, Malone J I, Strowig S, Ahern J A, Lavent F

Клиническое исследованиеСравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

This study compared glycemic control achieved with insulin lispro or buffered regular human insulin in patients with Type 1 diabetes treated with continuous subcutaneous insulin infusion (CSII) using an external insulin pump. In this 24-week multicenter, randomized, two-way crossover, open-label trial, 58 patients on CSII with adequate glycemic control received either insulin lispro or buffered regular human insulin for 12 weeks, followed by the alternate treatment for another 12 weeks. Efficacy and safety measures included hemoglobin A(1c) (HbA(1c)) at baseline and endpoint, home blood glucose monitoring, hypoglycemia, and frequency of pump catheter occlusion. Patients consumed a standard test meal on three occasions, with determinations of fasting, 1- and 2-h postprandial glucose values. Insulin lispro use was associated with a significantly lower HbA(1c) than was buffered regular human insulin (7.41+/-0.97 vs. 7.65+/-0.85 mmol/l; P=.004). Fasting serum glucose values before the test meal were similar between the two therapies. The 1-h (11.16+/-4.29 vs. 13.20+/-4.68 mmol/l; P=.012) and 2-h (9.64+/-4.10 vs. 12.53+/-4.64 mmol/l; P=.001) postprandial glucose concentrations were significantly lower during treatment with insulin lispro. No differences between treatments were observed in basal or bolus insulin doses, weight gain, or the incidence and rate of hypoglycemia, hyperglycemia, or pump occlusions. When used in external pumps, insulin lispro provides better glycemic control than buffered regular human insulin with a similar adverse event profile.

Для цитирования: Raskin P, Holcombe J H, Tamborlane W V, Malone J I, Strowig S, Ahern J A, Lavent F. A comparison of insulin lispro and buffered regular human insulin administered via continuous subcutaneous insulin infusion pump.. Journal of diabetes and its complications. 2001. DOI: 10.1016/s1056-8727(01)00168-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.