Characteristics of the Filtering Bleb and the Agreement between Glaucoma Specialist and Anterior Segment-Optical Coherence Tomography Assessment.

Zantut Fabio, Gracitelli Carolina Pelegrini Barbosa, Souza Paulo H, Teixeira Sergio H, Paranhos Augusto

СтатьяПеревод пока не подготовлен

Аннотация

INTRODUCTION

This study aimed to evaluate the characteristics of the filtering bleb in failed late trabeculectomy and the agreement between glaucoma specialist assessment and anterior segment-optical coherence tomography (AS-OCT) system assessment in terms of the presence of subconjunctival fluid in the filtering bleb.

METHODS

Patients with a diagnosis of glaucoma who were scheduled to undergo trabeculectomy in at least one eye and with uncontrolled intraocular pressure (IOP) were enrolled. All participants underwent a complete ophthalmological examination. The presence of fluid under the filtering bleb was first evaluated by a glaucoma specialist using biomicroscopy evaluation and then using the OCT 1000 AS-OCT Version 3.0.1.8 (Carl Zeiss Meditec, Dublin, CA, USA) system. A Kappa statistical test was used to evaluate the agreement between AS-OCT and the examiner. The correlation between conjunctiva and tenon thickness and clinical parameters was also assessed.

RESULTS

Forty eyes of 40 patients were evaluated in this study. The ages ranged from 21 to 86 years, with a mean of 66.55 ± 12.33. The average IOP was 21.20 ± 4.44 mm Hg (range 14-38 mm Hg) in the entire group. The mean thickness of the conjunctiva and tenon was 302.03 ± 406.76 µm (range 251-1,616 µm). There was a significant negative correlation between the mean thickness of the conjunctiva and tenon and IOP (p = 0.045; confidence interval = -0.558, 0.024). Additionally, there was a significant negative correlation between the mean thickness of the conjunctiva and tenon, and the number of medications used at baseline (p = 0.043; confidence interval = -0.538, 0.051). There was significant negative correlation between the horizontal measurement of the bleb and the use of glaucoma medications (p = 0.017; confidence interval = -0.560, 0.004). A total of 26 patients were determined to have fluid by the examiner (glaucoma expert), and the presence of fluid in AS was confirmed in 19 patients by AS-OCT. Of the 14 patients who were determined to have an absence of fluid, this was confirmed by AS-OCT in 7 patients (Kappa = 0.231; agreement of 65.00%).

CONCLUSION

There is fair agreement between glaucoma specialist assessment and AS-OCT assessment in terms of the presence of fluid in trabeculectomy. Our findings highlight the importance of AS-OCT in some patients before deciding upon a new intervention.

Для цитирования: Zantut Fabio, Gracitelli Carolina Pelegrini Barbosa, Souza Paulo H, Teixeira Sergio H, Paranhos Augusto. Characteristics of the Filtering Bleb and the Agreement between Glaucoma Specialist and Anterior Segment-Optical Coherence Tomography Assessment.. Ophthalmic research. 2020. DOI: 10.1159/000511642.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.