Is preoperative ciliary body and iris anatomical configuration a predictor of malignant glaucoma development?

Prata Tiago S, Dorairaj Syril, De Moraes Carlos G V, Mehta Siddhart, Sbeity Zaher, Tello Celso, Liebmann Jeffrey, Ritch Robert

СтатьяПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

To investigate anatomical configuration of ciliary body and iris using ultrasound biomicroscopy as a predictor of malignant glaucoma development.

DESIGN

Retrospective study in a tertiary care hospital.

PARTICIPANTS

Cohort of 31 consecutive patients diagnosed with post-surgical malignant glaucoma.

METHODS

Anterior chamber angle, iris and ciliary body configuration of involved eyes that had ultrasound biomicroscopy evaluation prior to the malignant glaucoma onset were evaluated. In cases with no presurgical ultrasound biomicroscopy exam of the involved eye, images from the fellow eye (imaged within 6 months) were analysed.

MAIN OUTCOME MEASURES: Qualitative parameters.

RESULTS

Thirty-one eyes (31 patients) had confirmed malignant glaucoma between 1996 and 2008. Most patients were women (65%) and had an anatomical narrow angle or angle-closure glaucoma (77%). Mean intraocular pressure at diagnosis was 30.4 ± 13.5 mmHg. The most common operation was trabeculectomy with mitomycin C (55%, 17/31 eyes), combined (3/17) or not (14/17) with cataract extraction and intraocular lens implantation. Among these 31 cases, we were able to evaluate the ultrasound biomicroscopy images of 13 patients (13 eyes) including involved eyes imaged prior to the malignant glaucoma onset or eligible fellow eyes. A narrow angle with or without iridotrabecular contact was found in all eyes. A large and/or anteriorly positioned ciliary body associated with an iris root angulating forward and centrally, revealing a plateau iris configuration, was noticed in 85% (11/13) of these eyes.

CONCLUSION

Identification of plateau iris configuration by ultrasound biomicroscopy should be considered as a possible predictor of post-operative malignant glaucoma development.

Для цитирования: Prata Tiago S, Dorairaj Syril, De Moraes Carlos G V, Mehta Siddhart, Sbeity Zaher, Tello Celso, Liebmann Jeffrey, Ritch Robert. Is preoperative ciliary body and iris anatomical configuration a predictor of malignant glaucoma development?. Clinical & experimental ophthalmology. 2013. DOI: 10.1111/ceo.12057.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.