Development of a Brain Catheter for Optical Coherence Tomography in Advanced Cerebrovascular Diagnostics.

Jung Tae-Mi, Nairuz Tahsin, Kim Chang-Hyun, Lee Jong-Ha

СтатьяПеревод пока не подготовлен

Аннотация

Optical coherence tomography (OCT) has been extensively utilized in cardiovascular diagnostics due to its high resolution, rapid imaging capabilities; however, its adaptation for cerebrovascular applications remains constrained by the narrow, tortuous anatomical structure of cerebral vessels. To address these limitations, this study introduces a cerebrovascular-specific OCT (bOCT) catheter, an advanced adaptation of the cardiovascular OCT (cOCT) catheter, with significant structural modifications for improved access to brain blood vessels. The bOCT catheter incorporates a braided wire within a braided tube, strategically reinforcing axial strength. The distal shaft was reconfigured as a single-lumen structure, facilitating unified movement of the rotating fiber optic core and guidewire, thereby reducing guidewire bending and augmenting force transmission stability. Additionally, the anterior protrusion was removed and replaced with a dual-lumen configuration, significantly enhancing lesion accessibility. The bOCT catheter's performance was validated in a 3D physical model and an animal model, demonstrating pronounced enhancements in flexibility, pushability, and navigability. Notably, the pushability through curved flow paths significantly improved, enhancing access to cerebral blood vessels. Therefore, this innovation promises to revolutionize cerebrovascular diagnostics with high-resolution imaging suited to the complex brain vasculature, setting a new standard in intravascular imaging technology.

Для цитирования: Jung Tae-Mi, Nairuz Tahsin, Kim Chang-Hyun, Lee Jong-Ha. Development of a Brain Catheter for Optical Coherence Tomography in Advanced Cerebrovascular Diagnostics.. Biosensors. 2025. DOI: 10.3390/bios15030170.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.