Journal of the neurological sciences · 2014
Safety evaluation of high-dose BCNU-loaded biodegradable implants in Chinese patients with recurrent malignant gliomas.
Клиническое исследование I фазыСтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Sai Ke, Zhong Ming-Gu, Wang Jian, Chen Yin-Sheng, Mou Yong-Gao, Ke Chao, Zhang Xiang-Heng, Yang Qun-Ying, Lin Fu-Hua, Guo Cheng-Cheng, Chen Zheng-He, Zeng Jing, Lv Yan-Chun, Li Xiang, Gao Wen-Chang, Chen Zhong-Ping
Аннотация
OBJECTIVES: Malignant gliomas are common primary brain tumors with dismal prognosis. The blood-brain barrier and unacceptable systemic toxicity limit the employment of chemotherapeutic agents. BCNU-impregnated biodegradable polymers (Gliadel®) have been demonstrated to prolong the survival of patients with malignant gliomas. Until now, no biodegradable drug delivery system has been commercially available in China. In the present study, we evaluated the safety of implants with high-dose BCNU in Chinese patients with recurrent malignant gliomas.
PATIENTS AND METHODS: Adults with supratentorial recurrent malignant glioma were eligible. High-dose BCNU-loaded PLGA implants (20mg of BCNU in each implant) were placed in the debulking cavity. The implants were investigated by a classical 3+3 design. Four levels of BCNU, up to 12 implants, were evaluated. Pharmacokinetic sampling was performed. The toxicity of the implants and the survival of patients were recorded.
RESULTS: Fifteen recurrent patients were enrolled with 12 glioblastomas and 3 anaplastic gliomas. Among 15 patients, 3 were treated with 3 implants (60 mg of BCNU), 3 with 6 implants (120 mg), 3 with 9 implants (180 mg) and 6 with 12 implants (240 mg). No dose-limiting toxicity was observed in the cohort of patients. Subgaleal effusion was the most common adverse event, presenting in 7 patients (46.7%). The median overall survival (OS) was 322 days (95% CI, 173-471 days). The 6-month, 1-year and 2-year survival rates were 66.7%, 40% and 13.3%, respectively.
CONCLUSIONS: The high-dose BCNU-loaded PLGA implants were safe for Chinese patients with recurrent malignant gliomas and further investigation for efficacy is warranted.
PATIENTS AND METHODS: Adults with supratentorial recurrent malignant glioma were eligible. High-dose BCNU-loaded PLGA implants (20mg of BCNU in each implant) were placed in the debulking cavity. The implants were investigated by a classical 3+3 design. Four levels of BCNU, up to 12 implants, were evaluated. Pharmacokinetic sampling was performed. The toxicity of the implants and the survival of patients were recorded.
RESULTS: Fifteen recurrent patients were enrolled with 12 glioblastomas and 3 anaplastic gliomas. Among 15 patients, 3 were treated with 3 implants (60 mg of BCNU), 3 with 6 implants (120 mg), 3 with 9 implants (180 mg) and 6 with 12 implants (240 mg). No dose-limiting toxicity was observed in the cohort of patients. Subgaleal effusion was the most common adverse event, presenting in 7 patients (46.7%). The median overall survival (OS) was 322 days (95% CI, 173-471 days). The 6-month, 1-year and 2-year survival rates were 66.7%, 40% and 13.3%, respectively.
CONCLUSIONS: The high-dose BCNU-loaded PLGA implants were safe for Chinese patients with recurrent malignant gliomas and further investigation for efficacy is warranted.
Предметные рубрики MeSH
Absorbable ImplantsAdolescentAdultAgedAntineoplastic Agents, AlkylatingAsian PeopleBrain NeoplasmsCarmustineDecanoic AcidsDose-Response Relationship, DrugFemaleFollow-Up StudiesGliomaHumansKarnofsky Performance StatusMagnetic Resonance ImagingMaleMiddle AgedNeoplasm Recurrence, LocalPolyestersYoung Adult