INTRODUCTION

The optimal tuberosity repair method in reverse total shoulder arthroplasty for fracture is unknown.

METHODS

Eight matched pairs of cadaver shoulders were randomly assigned to a stem-based tuberosity repair technique or a nonstem-based repair (Boileau technique) and mechanically tested with a 10 kN load cell. Cyclic loading was performed between 10 and 100 N for 500 cycles at 1 Hz, followed by static pull to failure at 33 mm/s. Ultimate load was determined from the maximum load reached during the pull to failure. A paired Student t-test was used to compare the means of the ultimate load and average cyclic displacement of the two sample groups.

RESULTS

The ultimate load to failure for the stem-based tuberosity repair technique was significantly higher than the nonstem-based technique (668 ± 164 N versus 483 ± 67 N; P = 0.032). The average cyclic displacement for the stem-based tuberosity repair technique was significantly less than the nonstem-based technique 0 (0.83 ± 0.67 mm versus 3.36 ± 2.36 mm; P = 0.017).

CONCLUSION

The stem-based tuberosity repair technique afforded higher ultimate load to failure with less average cyclic displacement than the nonstem-based technique. Consideration to the stem-based technique should be given when performing a tuberosity repair in the setting of reverse total shoulder arthroplasty for fracture.

LEVEL OF EVIDENCE: Level III.

Для цитирования: Erickson Brandon J, Shishani Yousef, Bishop Meghan E, Romeo Anthony A, Lederman Evan, Gobezie Reuben. Tuberosity Repair in Reverse Total Shoulder Arthroplasty for Fracture Using a Stem-based Double-row Repair: A Cadaveric Biomechanical Study.. The Journal of the American Academy of Orthopaedic Surgeons. 2020. DOI: 10.5435/jaaos-d-19-00667.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.