MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/01.mat.0000144366.11737.f0

Медицинская библиотека · ASAIO journal (American Society for Artificial Internal Organs : 1992) · 2004

Twenty-two year experience with the omniscience prosthetic heart valve.

Misawa Yoshio, Taguchi Masanobu, Aizawa Kei, Takahashi Hideki, Sakano Yasuhito, Kaminishi Yuichiro, Oki Shin-Ichi, Konishi Hiroaki, Saito Tsutomu, Kato Morito

СтатьяПеревод пока не подготовлен

Аннотация

This study was designed to evaluate the long-term clinical results of the Omniscience tilting disc valve. Omniscience valves were implanted in 51 patients (mean age, 50 +/- 10 years); 18 had aortic valve, 24 had mitral valve, and 9 had both aortic and mitral valve replacements. Oral warfarin potassium and dipyridamole were prescribed as our anticoagulant therapy. Preoperatively, 42 patients were in New York Heart Association class III or IV, and 23 of 25 surviving patients were in class I or II after operation. There were 2 (3.9%) early deaths and 23 late deaths (3.5 +/- 0.7% per patient-year). Cardiac related mortality including congestive heart failure, sudden death, and thromboembolism, and hemorrhagic complications were seen in 16 patients. Overall survival at 10, 15, and 20 years was 77 +/- 6%, 62 +/- 7%, and 46 +/- 7%, respectively. Thromboembolic complications were seen in 5 patients, for a rate of 0.8 +/- 0.3% per patient-year; similarly, hemorrhagic complications were also seen in 5 patients. Nonstructural prosthetic valve dysfunction was seen in 4 patients, for a rate of 0.6 +/- 0.3% per patient-year, and sudden death was seen in 2, a rate of 0.3 +/- 0.2% per patient-year. The Omniscience prosthesis demonstrated excellent postoperative clinical status with low rates of valve related complications.

Для цитирования: Misawa Yoshio, Taguchi Masanobu, Aizawa Kei, Takahashi Hideki, Sakano Yasuhito, Kaminishi Yuichiro, Oki Shin-Ichi, Konishi Hiroaki, Saito Tsutomu, Kato Morito. Twenty-two year experience with the omniscience prosthetic heart valve.. ASAIO journal (American Society for Artificial Internal Organs : 1992). 2004. DOI: 10.1097/01.mat.0000144366.11737.f0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.