T-cell numbers and antigen-specific T-cell function follow different circadian rhythms.
Аннотация
PURPOSE: Circadian rhythms play an important role in modulating cellular immune responses. The present study was performed to characterise circadian variations in lymphocyte numbers and antigen-specific T-cell functionality in healthy individuals under physiological conditions.
METHODS
Blood leukocyte populations of six healthy volunteers were quantified over 24 h. In addition, antigen-specific T-cell functionality was analysed directly ex vivo from whole blood using flow cytometry based on intracellular cytokine induction after a 6-hour stimulation with adenovirus antigen and Staphylococcus aureus enterotoxin B (SEB), respectively.
RESULTS
T-cell numbers and reactivity were stable during daytime, whereas a significant increase was observed during late evening and early morning hours. The percentage of T cells reacting towards adenovirus antigen and SEB showed a 1.76 ± 0.55-fold (p = 0.0002) and a 1.42 ± 0.33-fold (p = 0.0002) increase, respectively. Dynamics in T-cell reactivity were independent of the mode of antigen stimulation and inversely correlated with plasma levels of endogenous cortisol. Interestingly, peak frequencies of reactive T cells occurred late in the evening and did not directly coincide with peak numbers of bulk T cells that were observed in the early morning hours.
CONCLUSIONS
Taken together, our data reveal a circadian regulation of T-cell immune responses in the peripheral blood of humans under physiological conditions. This knowledge may be of practical consequence for the timing of blood sampling for functional T-cell assays as well as for immunosuppressive drug intake after organ transplantation, where T-cell function may be influenced not only by drug-mediated inhibition but also by circadian fluctuations in T-cell reactivity.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.