MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3350/cmh.2024.0392

Медицинская библиотека · Clinical and molecular hepatology · 2024

Optimal cut-offs of vibration-controlled transient elastography and magnetic resonance elastography in diagnosing advanced liver fibrosis in patients with nonalcoholic fatty liver disease: A systematic review and meta-analysis.

Chon Young Eun, Jin Young-Joo, An Jihyun, Kim Hee Yeon, Choi Miyoung, Jun Dae Won, Kim Mi Na, Han Ji Won, Lee Han Ah, Yu Jung Hwan, Kim Seung Up

СтатьяСистематический обзорМетаанализПеревод пока не подготовлен

Аннотация

BACKGROUND/AIMS: Opinions differ regarding vibration-controlled transient elastography and magnetic resonance elastography (VCTE/MRE) cut-offs for diagnosing advanced fibrosis (AF) in patients with non-alcoholic fatty liver disease (NAFLD). We investigated the diagnostic performance and optimal cut-off values of VCTE and MRE for diagnosing AF.

METHODS

Literature databases, including Medline, EMBASE, Cochrane Library, and KoreaMed, were used to identify relevant studies published up to June 13, 2023. We selected studies evaluating VCTE and MRE regarding the degree of liver fibrosis using liver biopsy as the reference. The sensitivity, specificity, and area under receiver operating characteristics curves (AUCs) of the pooled data for VCTE and MRE for each fibrosis stage and optimal cut-offs for AF were investigated.

RESULTS

A total of 19,199 patients from 63 studies using VCTE showed diagnostic AUC of 0.83 (95% confidence interval: 0.80-0.86), 0.83 (0.80-0.86), 0.87 (0.84-0.90), and 0.94 (0.91-0.96) for ≥F1, ≥F2, ≥F3, and F4 stages, respectively. Similarly, 1,484 patients from 14 studies using MRE showed diagnostic AUC of 0.89 (0.86-0.92), 0.92 (0.89-0.94), 0.89 (0.86-0.92), and 0.94 (0.91-0.96) for ≥F1, ≥F2, ≥F3, and F4 stages, respectively. The diagnostic AUC for AF using VCTE was highest at 0.90 with a cut-off of 7.1-7.9 kPa, and that of MRE was highest at 0.94 with a cut-off of 3.62-3.8 kPa.

CONCLUSION

VCTE (7.1-7.9 kPa) and MRE (3.62-3.8 kPa) with the suggested cut-offs showed favorable accuracy for diagnosing AF in patients with NAFLD. This result will serve as a basis for clinical guidelines for non-invasive tests and differential diagnosis of AF.

Для цитирования: Chon Young Eun, Jin Young-Joo, An Jihyun, Kim Hee Yeon, Choi Miyoung, Jun Dae Won, Kim Mi Na, Han Ji Won, Lee Han Ah, Yu Jung Hwan, Kim Seung Up. Optimal cut-offs of vibration-controlled transient elastography and magnetic resonance elastography in diagnosing advanced liver fibrosis in patients with nonalcoholic fatty liver disease: A systematic review and meta-analysis.. Clinical and molecular hepatology. 2024. DOI: 10.3350/cmh.2024.0392.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.