MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2319/080919-523.1

Медицинская библиотека · The Angle orthodontist · 2020

The Class II Carriere Motion appliance.

Areepong Daniel, Kim Ki Beom, Oliver Donald R, Ueno Hiroshi

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

To determine three-dimensional treatment changes produced by the Class II Carriere Motion appliance (CMA) in Class II adolescent patients with Class I and Class II skeletal relationships.

MATERIALS AND

METHODS

The sample included 59 adolescents (16 boys and 43 girls) with unilateral or bilateral Class II molar and bilateral Class II canine relationship. They were divided into group 1 with skeletal Class I (N = 27; ANB 2.90° ± 1.40°; 13.30 ± 1.53 years) and group 2 with skeletal Class II (N = 32; ANB 6.06° ± 1.64°; 13.26 ± 1.76 years). Cone beam computed tomography images were traced with Invivo software pretreatment (T1) and post-CMA usage (T2). The treatment changes in 36 measurements were calculated in each group, and the changes in 16 measurements were compared between them.

RESULTS

In group 1 and 2, maxillary first molars underwent significant distal movement (1.92 mm ± 0.80 mm and 1.67 mm ± 1.56 mm, respectively) with distal tipping and rotation, maxillary canines underwent significant distal movement (2.34 mm ± 1.07 mm and 2.24 mm ± 1.91 mm, respectively) with distal tipping and rotation, and mandibular molars underwent significant mesial movement (-1.37 mm ± 1.23 mm and -2.51 mm ± 1.51 mm, respectively) with mesial tipping. Between the groups, there were significant differences in mandibular molar mesial movement and the U1-SN changes (P < .05).

CONCLUSIONS

The CMA corrected Class II malocclusion through distal tipping and rotational movement of maxillary canines and molars and corrected mesial tipping of mandibular molars. Significantly more mandibular molar mesial movement and maxillary incisor flaring were observed in patients with skeletal Class II.

Для цитирования: Areepong Daniel, Kim Ki Beom, Oliver Donald R, Ueno Hiroshi. The Class II Carriere Motion appliance.. The Angle orthodontist. 2020. DOI: 10.2319/080919-523.1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.