DOI 10.13201/j.issn.2096-7993.2024.02.006
[Application of the follower arm endoscope holder in type i tympanoplasty].
Аннотация
Objective
To investigate the surgical outcomes and safety of the follower arm endoscope holder in assisting type Ⅰ tympanoplasty.
Methods
The clinical data of 16 patients who underwent type Ⅰ tympanoplasty at the Department of Otorhinolaryngology, Peking Union Medical College Hospital, from November 2022 to September 2023 were retrospectively analyzed, among which 8 cases were operated by traditional otoscopy and 8 cases were operated by supported endoscopy.The surgical procedure was analyzed and the completion of supported endoscopic operation was observed, while the duration of the operation, the time consumed by the main steps, the frequency of wiping the lenses, the perioperative complications, and the improvement of the postoperative hearing were recorded and statistically analyzed.
Results
Supporting endoscopic technology achieved real-time suction of bleeding, simultaneous traction and separation of tissues, precise removal of calcified spots on the inner side of the eardrum, trimming of the external auditory canal flap, stable separation of the handle of the malleus and the eardrum, and tensioned repositioning of the skin-cartilage flap. The average duration of surgery, time for external auditory canal flap preparation, and time for repositioning the skin-cartilage flap were reduced in the supporting endoscopic surgery group compared to the control group. The average lens wiping frequency was significantly lower in the supporting endoscopic surgery group compared to the control group. There was no statistically significant difference in postoperative hearing improvement between the two groups, and no infections or the need for secondary surgery due to eardrum re-perforation occurred postoperatively.
Conclusion
Supported endoscopy technology realizes the need for endoscopic two-handed operation and convenient switching between one and two hands, accomplishes many operations that cannot be done by traditional endoscopic surgery, solves the problems of previous intraoperative one-handed operation and image instability, shortens the average operation time compared with traditional otoscopic surgery, and decreases the frequency of intraoperative wiping of the lens significantly compared with traditional otoscopic surgery, which is potentially worthwhile in terms of shortening the learning curve.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.