Медицинская библиотека · Journal of medical economics · 2020

Resource utilization associated with hospital and office-based insertion of a miniaturized insertable cardiac monitor: results from the RIO 2 randomized US study.

Rogers John D, Piorkowski Christopher, Sohail M Rizwan, Anand Rishi, Kowalski Marcin, Rosemas Sarah, Stromberg Kurt, Sanders Prashanthan

СтатьяМногоцентровое исследованиеРандомизированное исследованиеПеревод пока не подготовлен

Аннотация

Background

Previous studies support operational benefits when moving insertable cardiac monitor (ICM) insertions outside the cardiac catheterization/electrophysiology laboratories, but this has not been directly assessed in a randomized trial or when the procedure is specifically moved to the office setting. To gain insight, the RIO 2 US study collected resource utilization and procedure time intervals for ICM insertion in-office and in-hospital and these data were used to calculate costs associated with staff time and supply use in each setting.Methods and results: The Reveal LINQ In-Office 2 US study (randomized [1:1], multicenter, unblinded) included 482 patients to undergo insertion of the ICM in-hospital (in an operating room or CATH/EP laboratory) (n = 251) or in-office (n = 231). Detailed information on resource utilization was collected prospectively by the study and used to compare resource utilization and procedure time intervals during ICM insertion procedures performed in-office vs. in-hospital. In addition, costs associated with staff time and supply use in each setting were calculated retrospectively. Total visit duration (check-in to discharge) was 107 min shorter in-office vs. in-hospital (95% CI = 97-116 min; p < 0.001). Patient preparation and education in-office were more likely to occur in the same room as the procedure, compared with in-hospital (91.6% vs. 34.2%, p < 0.001 and 87.3% vs. 22.1%, p < 0.001, respectively). There was a reduction in registered nurse and cardiovascular/operating room technologist involvement in-office, accompanied by higher physician and medical assistant participation. Overall staff time spent per case was 75% higher in-hospital, leading to 50% higher staffing costs compared to in-office.

Conclusions

ICM insertion in a physician's office vs. a hospital setting resulted in reduced patient visit time and reduced overall staff time, with a consequent reduction in staffing costs. Clinical trial registration: ClinicalTrials.gov NCT02395536.

Для цитирования: Rogers John D, Piorkowski Christopher, Sohail M Rizwan, Anand Rishi, Kowalski Marcin, Rosemas Sarah, Stromberg Kurt, Sanders Prashanthan. Resource utilization associated with hospital and office-based insertion of a miniaturized insertable cardiac monitor: results from the RIO 2 randomized US study.. Journal of medical economics. 2020. DOI: 10.1080/13696998.2020.1746548.