m+Medelevator.RU
← Поиск публикаций
Journal of synchrotron radiation · 2016

A robust method for high-precision quantification of the complex three-dimensional vasculatures acquired by X-ray microtomography.

СтатьяПоддержка исследования: вне правительства СШАНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Tan Hai, Wang Dadong, Li Rongxin, Sun Changming, Lagerstrom Ryan, He You, Xue Yanling, Xiao Tiqiao

Аннотация

The quantification of micro-vasculatures is important for the analysis of angiogenesis on which the detection of tumor growth or hepatic fibrosis depends. Synchrotron-based X-ray computed micro-tomography (SR-µCT) allows rapid acquisition of micro-vasculature images at micrometer-scale spatial resolution. Through skeletonization, the statistical features of the micro-vasculature can be extracted from the skeleton of the micro-vasculatures. Thinning is a widely used algorithm to produce the vascular skeleton in medical research. Existing three-dimensional thinning methods normally emphasize the preservation of topological structure rather than geometrical features in generating the skeleton of a volumetric object. This results in three problems and limits the accuracy of the quantitative results related to the geometrical structure of the vasculature. The problems include the excessively shortened length of elongated objects, eliminated branches of blood vessel tree structure, and numerous noisy spurious branches. The inaccuracy of the skeleton directly introduces errors in the quantitative analysis, especially on the parameters concerning the vascular length and the counts of vessel segments and branching points. In this paper, a robust method using a consolidated end-point constraint for thinning, which generates geometry-preserving skeletons in addition to maintaining the topology of the vasculature, is presented. The improved skeleton can be used to produce more accurate quantitative results. Experimental results from high-resolution SR-µCT images show that the end-point constraint produced by the proposed method can significantly improve the accuracy of the skeleton obtained using the existing ITK three-dimensional thinning filter. The produced skeleton has laid the groundwork for accurate quantification of the angiogenesis. This is critical for the early detection of tumors and assessing anti-angiogenesis treatments.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты