MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/dmfr/twaf009

Медицинская библиотека · Dento maxillo facial radiology · 2025

Development and assessment of a prototype of an interproximal image receptor-holding device for use in paediatric dentistry.

Ocampo Thais, Alencar-Palha Caio, Cascante-Sequeira Deivi, Réa Marcela Tarosso, Freitas Deborah Queiroz, Haiter-Neto Francisco

СтатьяПеревод пока не подготовлен

Аннотация

To develop and test a prototype for interproximal radiography positioning intended for paediatric dentistry and compare the technical quality of image receptor-holding devices (IRHDs) commonly used in clinical practice. Six prototypes, with 3 wedge dimensions (0.5, 1, and 2 mm, respectively) in upper and lower positions on the bitewing surface were compared regarding their capacity to acquire interproximal radiographs without overlapping surfaces with other IRHDs: RinnXCP, Hawe Kerr, and Cone Indicator. Fifteen graduate students obtained images of deciduous molars in a child's skull and mandible. The chi-square and Fisher's exact tests were employed to analyse significant differences in the number of repetitions and failures in obtaining correct images. A one-way analysis of variance (ANOVA) assessed the difference between the mean times required for image acquisition according to each IRHD, adopting a significance level of 5%. The effectiveness of the tested devices, evaluated by the number of correct and incorrect acquisitions using Fisher's exact test, revealed a P-value of .057. The ANOVA demonstrated statistically significant differences in the mean acquisition times (P < .0000). The upper and lower wedge prototypes 2 mm performed better in acquiring only 1 radiograph (76.7%) and took less time to execute the technique (1.17 and 1.12 min, respectively). The prototypes showed comparable performance to alternative IRHDs but provided advantages in time efficiency and radiation exposure.

Для цитирования: Ocampo Thais, Alencar-Palha Caio, Cascante-Sequeira Deivi, Réa Marcela Tarosso, Freitas Deborah Queiroz, Haiter-Neto Francisco. Development and assessment of a prototype of an interproximal image receptor-holding device for use in paediatric dentistry.. Dento maxillo facial radiology. 2025. DOI: 10.1093/dmfr/twaf009.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.