MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/mrm.30368

Медицинская библиотека · Magnetic resonance in medicine · 2024

Proton-free induction decay MRSI at 7 T in the human brain using an egg-shaped modified rosette K-space trajectory.

Blömer Simon, Hingerl Lukas, Marjańska Małgorzata, Bogner Wolfgang, Motyka Stanislav, Hangel Gilbert, Klauser Antoine, Andronesi Ovidiu C, Strasser Bernhard

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: Proton (1H)-MRSI via spatial-spectral encoding poses high demands on gradient hardware at ultra-high fields and high-resolutions. Rosette trajectories help alleviate these problems, but at reduced SNR-efficiency because of their k-space densities not matching any desired k-space filter. We propose modified rosette trajectories, which more closely match a Hamming filter, and thereby improve SNR performance while still staying within gradient hardware limitations and without prolonging scan time.

METHODS

Analytical and synthetic simulations were validated with phantom and in vivo measurements at 7 T. The rosette and modified rosette trajectories were measured in five healthy volunteers in 6 min in a 2D slice in the brain. An elliptical phase-encoding sequence was measured in one volunteer in 22 min, and a 3D sequence was measured in one volunteer within 19 min. The SNR per-unit-time, linewidth, Cramer-Rao lower bounds (CRLBs), lipid contamination, and data quality of the proposed modified rosette trajectory were compared to the rosette trajectory.

RESULTS

Using the modified rosette trajectories, an improved k-space weighting function was achieved resulting in an SNR per-unit-time increase of up to 12% compared to rosette's and 23% compared to elliptical phase-encoding, dependent on the two additional trajectory parameters. Similar results were achieved for the theoretical SNR calculation based on k-space densities, as well as when using the pseudo-replica method for simulated, in vivo, and phantom data. The CRLBs of γ-aminobutyric acid and N-acetylaspartylglutamate improved non-significantly for the modified rosette trajectory, whereas the linewidths and lipid contamination remained similar.

CONCLUSION

By optimizing the shape of the rosette trajectory, the modified rosette trajectories achieved higher SNR per-unit-time and enhanced data quality at the same scan time.

Для цитирования: Blömer Simon, Hingerl Lukas, Marjańska Małgorzata, Bogner Wolfgang, Motyka Stanislav, Hangel Gilbert, Klauser Antoine, Andronesi Ovidiu C, Strasser Bernhard. Proton-free induction decay MRSI at 7 T in the human brain using an egg-shaped modified rosette K-space trajectory.. Magnetic resonance in medicine. 2024. DOI: 10.1002/mrm.30368.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.