MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jped.2020.01.005

Медицинская библиотека · Jornal de pediatria · 2020

Multichannel intraluminal impedance-pH and psychometric properties in gastroesophageal reflux: systematic review.

Gonçalves Emília Silva, Assumpção Maíra Seabra de, Servidoni Maria Fátima Correa Pimenta, Lomazi Elizete Aparecida, Ribeiro José Dirceu

СтатьяСистематический обзорПеревод пока не подготовлен

Аннотация

OBJECTIVE

Systematically assess studies that have analyzed the psychometric properties of multichannel intraluminal impedance-pH for the diagnosis of gastroesophageal reflux. Systematically verify studies that have analyzed the psychometric properties of multichannel intraluminal impedance-pH regarding the diagnosis of gastroesophageal reflux disease in pediatric patients.

METHODS

Systematic review considering specific descriptors (children and adolescents, gastroesophageal reflux disease and multichannel intraluminal impedance-pH) and their synonyms. The systematic search was carried out in the MEDLINE/Ovid, Scopus, and Embase databases, considering the period from October 2017 to December 2018. This review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA), which was used for study selection. The psychometric properties described in the studies were: sensitivity, specificity, accuracy, and reproducibility.

RESULTS

Sensitivity was discussed in most studies, with a result of more than 70% in four of them. Specificity was assessed only in conjunction with sensitivity, with values from 23% to 25% in two studies, and it reached 80% in a single study. Accuracy was assessed higher than 76% in one of the selected articles. The methodological quality of the studies demonstrated low risk of bias, and there was no significant concern related to applicability of the studies.

CONCLUSIONS

According to the selected studies, multichannel intraluminal impedance-pH was considered a safe and effective tool, presenting higher sensitivity values than pHmetry regarding the diagnosis of gastroesophageal reflux disease.

Для цитирования: Gonçalves Emília Silva, Assumpção Maíra Seabra de, Servidoni Maria Fátima Correa Pimenta, Lomazi Elizete Aparecida, Ribeiro José Dirceu. Multichannel intraluminal impedance-pH and psychometric properties in gastroesophageal reflux: systematic review.. Jornal de pediatria. 2020. DOI: 10.1016/j.jped.2020.01.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.