MedElevator Войти в исследования
← Поиск публикаций
Journal of clinical gastroenterology · 2025

Endoscopic Ultrasound-guided Transmural Biliary Drainage With 6 mm and 8 mm Cautery-enhanced Lumen-apposing Metal Stents: A Multicenter Collaborative Study.

СтатьяМногоцентровое исследованиеНазвание и аннотация: Перевод пока не подготовлен
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Ramai Daryl, Dawod Enad, Darwin Peter E, Kim Raymond E, Kim Jeong Hoon, Wang Jade, Lanka Chandana, Bakain Tarek, Mahadev SriHari, Sampath Kartik, Carr-Locke David L, Morris John D, Sharaiha Reem Z

Аннотация

OBJECTIVE: Endoscopic retrograde cholangiopancreatography (ERCP) may be unsuccessful in patients with duodenal stenosis or malignant ampullary infiltration. Endoscopic ultrasound-guided biliary drainage (EUS-BD) has been proposed as an alternative. We aimed to assess the efficacy and safety of EUS-BD for malignant distal bile duct obstruction using the newly introduced smaller caliber 6 or 8 mm cautery-enhanced lumen-apposing metal stent.

METHODS: A multicenter retrospective study was performed on patients with unresectable malignant distal bile duct obstruction who underwent EUS-BD between 2021 and 2022 after unsuccessful ERCP.

RESULTS: Thirty-two patients were included [7 (53.13%) males], with a mean age of 72.2 ± 12.5 years. The technical success rate was 100%. Altered anatomy was present in 2 (6.25%). The indication for drainage was biliary obstruction from pancreatic cancer in 26 patients (84.5%), cholangiocarcinoma in 3 (9.4%), and ampullary mass in 3 (9.4%). The procedure was performed mostly in an outpatient setting (n = 19, 59.38%). The clinical success rate was 92.3% [bilirubin: 14.1 (SD: 8.9) preprocedure vs 4.9 (SD: 1.1) postprocedure; P = 0.0001]. There was one early adverse event of a perforation, which was closed endoscopically and drained percutaneously. Delayed adverse events included food impaction of the stent (n = 1), which was resolved with a repeat procedure and insertion of a double pigtail stent.

CONCLUSION: This study demonstrates the feasibility of EUS-BD drainage using smaller caliber 6 or 8 mm lumen-apposing metal stent to relieve malignant distal bile duct obstruction in patients who fail conventional ERCP.

Предметные рубрики MeSH