MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/0309364615610660

Медицинская библиотека · Prosthetics and orthotics international · 2015

Marker-based method to measure movement between the residual limb and a transtibial prosthetic socket.

Childers Walter Lee, Siebert Steven

СтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Limb movement between the residuum and socket continues to be an underlying factor in limb health, prosthetic comfort, and gait performance yet techniques to measure this have been underdeveloped.

OBJECTIVES

Develop a method to measure motion between the residual limb and a transtibial prosthetic socket.

STUDY

DESIGN

Single subject, repeated measures with mathematical modeling.

METHODS

The gait of a participant with transtibial amputation was recorded using a motion capture system using a marker set that included arrays on the anterior distal tibia and the lateral epicondyle of the femur. The proximal or distal translation, anterior or posterior translation, and angular movements were quantified. A random Monte Carlo simulation based on the precision of the motion capture system and a model of the bone moving under the skin explored the technique's accuracy. Residual limb tissue stiffness was modeled as a linear spring based on data from Papaioannou et al.

RESULTS

Residuum movement relative to the socket went through ~30 mm, 18 mm, and 15° range of motion. Root mean squared errors were 5.47 mm, 1.86 mm, and 0.75° when considering the modeled bone-skin movement in the proximal or distal, anterior or posterior, and angular directions, respectively.

CONCLUSION

The measured movement was greater than the root mean squared error, indicating that this method can measure motion between the residuum and socket.

CLINICAL RELEVANCE: The ability to quantify movement between the residual limb and the prosthetic socket will improve prosthetic treatment through the evaluation of different prosthetic suspensions, socket designs, and motor control of the prosthetic interface.

Для цитирования: Childers Walter Lee, Siebert Steven. Marker-based method to measure movement between the residual limb and a transtibial prosthetic socket.. Prosthetics and orthotics international. 2015. DOI: 10.1177/0309364615610660.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.