DOI 10.1016/j.apmr.2015.08.435
Using Wearable Sensors and Machine Learning Models to Separate Functional Upper Extremity Use From Walking-Associated Arm Movements.
Аннотация
OBJECTIVE
To improve measurement of upper extremity (UE) use in the community by evaluating the feasibility of using body-worn sensor data and machine learning models to distinguish productive prehensile and bimanual UE activity use from extraneous movements associated with walking.
DESIGN
Comparison of machine learning classification models with criterion standard of manually scored videos of performance in UE prosthesis users.
SETTING
Rehabilitation hospital training apartment.
PARTICIPANTS
Convenience sample of UE prosthesis users (n=5) and controls (n=13) similar in age and hand dominance (N=18).
INTERVENTIONS: Participants were filmed executing a series of functional activities; a trained observer annotated each frame to indicate either UE movement directed at functional activity or walking. Synchronized data from an inertial sensor attached to the dominant wrist were similarly classified as indicating either a functional use or walking. These data were used to train 3 classification models to predict the functional versus walking state given the associated sensor information. Models were trained over 4 trials: on UE amputees and controls and both within subject and across subject. Model performance was also examined with and without preprocessing (centering) in the across-subject trials.
MAIN OUTCOME MEASURE: Percent correct classification.
RESULTS
With the exception of the amputee/across-subject trial, at least 1 model classified >95% of test data correctly for all trial types. The top performer in the amputee/across-subject trial classified 85% of test examples correctly.
CONCLUSIONS
We have demonstrated that computationally lightweight classification models can use inertial data collected from wrist-worn sensors to reliably distinguish prosthetic UE movements during functional use from walking-associated movement. This approach has promise in objectively measuring real-world UE use of prosthetic limbs and may be helpful in clinical trials and in measuring response to treatment of other UE pathologies.