MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/prs.0000000000001777

Медицинская библиотека · Plastic and reconstructive surgery · 2015

The Use of Pulse Oximetry for Objective Quantification of Vascular Injuries in the Hand.

Tarabadkar Neil, Iorio Matthew L, Gundle Kenneth, Friedrich Jeffrey B

Clinical StudyСтатьяПеревод пока не подготовлен

Аннотация

BACKGROUND

Efficient identification of dysvascular finger(s) following trauma is critical for triaging surgical care and optimizing patient outcomes. The authors designed a study evaluating an objective measure of digital hypoxia followed by surgical exploration and correlation with vascular injury.

METHODS

Patients with lacerating or penetrating trauma to the hand or digits were examined. A pulse oximeter was applied to the injured digit, and the oxygen saturation was recorded. The nonparametric Wilcoxon rank sum test was used to assess for differences in pulse oximetry for digits with and without an ischemic-type injury that required repair. Receiver operating characteristic curve analyses were used to determine cut-points.

RESULTS

Twenty patients with digital lacerations were enrolled, with a total of 49 digit measurements of pulse oximetry. Twelve dysvascular injuries requiring repair or amputation were confirmed in the operating room. There was a significant difference in pulse oximetry measurement in digits with (76 percent; 95 percent CI, 64 to 87 percent) and without (98 percent; 95 percent CI, 97 to 99 percent) ischemic injury (p < 0.001). Injured digits ranged in pulse oximetry values from 53 to 92 percent.

CONCLUSIONS

Pulse oximetry is widely available and offers an objective measure of tissue oxygenation. No digit with a pulse oximetry value of at least 95 percent had an ischemic injury, and all digits with a pulse oximetry value of 84 percent or lower required operative vascular treatment. Based on these data, pulse oximetry should be adopted as a routine measure for the evaluation and communication of a potentially dysvascular digit.

Для цитирования: Tarabadkar Neil, Iorio Matthew L, Gundle Kenneth, Friedrich Jeffrey B. The Use of Pulse Oximetry for Objective Quantification of Vascular Injuries in the Hand.. Plastic and reconstructive surgery. 2015. DOI: 10.1097/prs.0000000000001777.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.