DOI 10.2967/jnumed.108.059642

Медицинская библиотека · Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2009

Comparison of 3 methods of automated internal carotid segmentation in human brain PET studies: application to the estimation of arterial input function.

Zanotti-Fregonara Paolo, Maroy Renaud, Comtat Claude, Jan Sebastien, Gaura Véronique, Bar-Hen Avner, Ribeiro Maria-Joao, Trébossen Régine

Сравнительное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

UNLABELLED: Quantitative brain (18)F-FDG PET studies often require the plasma time-activity curve (input function) for estimation of the cerebral metabolic rate of glucose (CMRglc). The gold standard for input function measurement is arterial blood sampling, which is invasive and time-consuming. Alternatively, input function can be estimated from dynamic images. This estimation often implies the use of manually placed regions of interest (ROIs) over cerebral vasculature, which is an operator-dependent and time-consuming task. The aim of our study was to compare 3 algorithms of image segmentation (local means analysis [LMA], soft-decision similar component analysis [SCA], and k-means) to automatically segment internal carotid arteries from dynamic (18)F-FDG brain studies.

METHODS

The accuracy of automatic carotid segmentation algorithms was first tested using numeric phantoms of the human brain, by quantitatively assessing the overlap between the segmented carotids and the reference regions in the phantom. Then, the algorithm that yielded the best results was applied to data from 4 healthy volunteers, who underwent an (18)F-FDG dynamic 3-dimensional PET brain study. Concordance between manual and automatic ROIs, both uncorrected and after partial-volume effect and spillover correction, was first assessed. Linear regression was then used to compare manual versus automatic CMRglc values obtained using Patlak analysis. CMRglc values obtained by arterial sampling were used as a reference.

RESULTS

In phantom studies, LMA was shown to be superior to the other segmentation algorithms. By visual inspection, volunteers' internal carotids segmented by LMA were anatomically relevant. No significant difference was found between ROI values obtained by manual and automatic segmentation, either uncorrected or corrected for partial-volume effect. Linear regression demonstrated excellent agreement between the manual and automatic image-derived CMRglc values (P < 0.0001), and both correlated well with the reference values obtained by plasma samples.

CONCLUSION

The LMA segmentation algorithm allows accurate automatic delineation of internal carotids from dynamic PET brain studies. After correction for partial-volume effect, the main application would be the estimation of an image-derived input function.

Для цитирования: Zanotti-Fregonara Paolo, Maroy Renaud, Comtat Claude, Jan Sebastien, Gaura Véronique, Bar-Hen Avner, Ribeiro Maria-Joao, Trébossen Régine. Comparison of 3 methods of automated internal carotid segmentation in human brain PET studies: application to the estimation of arterial input function.. Journal of nuclear medicine : official publication, Society of Nuclear Medicine. 2009. DOI: 10.2967/jnumed.108.059642.