MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/01.inf.0000091887.48999.77

Медицинская библиотека · The Pediatric infectious disease journal · 2003

Safety, immunogenicity and efficacy in healthy infants of G1 and G2 human reassortant rotavirus vaccine in a new stabilizer/buffer liquid formulation.

Clark H Fred, Burke Carl J, Volkin David B, Offit Paul, Ward Richard L, Bresee Joseph S, Dennehy Penelope, Gooch W Manfred, Malacaman Edgardo, Matson David, Walter Emmanuel, Watson Barbara, Krah David L, Dallas Michael J, Schödel Florian, Kaplan karen M, Heaton Penny

Клиническое исследованиеСравнительное исследованиеСтатьяМногоцентровое исследованиеРандомизированное исследованиеПоддержка исследования: вне правительства СШАПеревод пока не подготовлен

Аннотация

BACKGROUND

A refrigerator-stable rotavirus (RV) vaccine that withstands gastric acid is anticipated to permit more widespread use of RV vaccine.

OBJECTIVE

We investigated for the first time in infants an oral, liquid formulation of G1 and G2 human bovine reassortant rotavirus vaccine (HRRV) with a new stabilizer/buffer (S/B) containing sucrose, sodium phosphate and sodium citrate.

METHODS

During 1997 through 1998, 731 healthy infants approximately 2 to 4 months of age were enrolled at 19 US sites to receive 3 HRRV or placebo doses approximately 6 to 8 weeks apart in a partially double blinded study. Infants were randomized to: (1) HRRV with no S/B but with prefeeding; (2) HRRV plus 1 of 3 different concentrations/volumes of S/B; or (3) placebo.

RESULTS

No serious vaccine-related adverse experiences or intussusception cases were reported. No statistically significant differences were observed between vaccine and placebo recipients for fever (> or =38.1 degrees C) 0 to 7 days after any dose, irritability, vomiting or diarrhea incidence 0 to 42 days after any dose. Vaccine virus shedding among vaccine recipients was uncommon. Among S/B vaccine groups, proportions of infants with a > or =3-fold titer rise from baseline to Postdose 3 for G1 serum-neutralizing antibody (SNA), G2 SNA, WC3 SNA, serum anti-RV IgA, serum anti-RV IgG and stool anti-RV IgA were generally similar to those of the prefed non-S/B group.

CONCLUSIONS

HRRV with a new S/B was generally well-tolerated; immunogenicity was generally similar to the prefed non-S/B group. No intussusception cases were reported, but the small sample size precluded a definitive conclusion. A large international clinical study is under way to address safety and efficacy of an S/B formulation of a pentavalent version of HRRV.

Для цитирования: Clark H Fred, Burke Carl J, Volkin David B, Offit Paul, Ward Richard L, Bresee Joseph S, Dennehy Penelope, Gooch W Manfred, Malacaman Edgardo, Matson David, Walter Emmanuel, Watson Barbara, Krah David L, Dallas Michael J, Schödel Florian, Kaplan karen M, Heaton Penny. Safety, immunogenicity and efficacy in healthy infants of G1 and G2 human reassortant rotavirus vaccine in a new stabilizer/buffer liquid formulation.. The Pediatric infectious disease journal. 2003. DOI: 10.1097/01.inf.0000091887.48999.77.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.