MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/00365521.2020.1806351

Медицинская библиотека · Scandinavian journal of gastroenterology · 2020

Benign biliary strictures treated with biodegradable stents in patients with surgically altered anatomy using double balloon enteroscopy.

Lindström Outi, Udd Marianne, Rainio Mia, Nuutinen Hannu, Jokelainen Kalle, Kylänpää Leena

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVES

Surgically altered anatomy complicates endoscopical procedures of pancreatobiliary tree. Biliary or hepaticojejunal anastomosis strictures have been managed using percutaneous transhepatic or double balloon enteroscopy (DBE) techniques with multiple plastic stents, or fully covered self-expandable metal stents. We report the first seven cases with surgically altered anatomy treated with biodegradable stents with DBE.

MATERIALS AND

METHODS

Seven cases with altered anatomy, all with Roux-en-Y hepaticojejunostomy (HJ), were treated for HJ anastomosis strictures (3 cases) and intrahepatic biliary stricture (4 cases). Fujifilm DB enteroscope with a 200 cm long and 3.2 mm wide working channel was used. Balloon dilatations were first performed and then 1-3 biodegradable stents were deployed with a pusher over a guidewire.

RESULTS

Two patients had HJ due to liver resections, one due to biliary injury in cholecystectomy and four due to liver transplantation because of primary sclerosing cholangitis (PSC). Median duration of the procedures was 56 min. Deployment of the stents took less than 20 min per patient. There were no stent or cholangiography related adverse events, but one patient required endotracheal intubation for nose bleeding caused by the placement of nasopharyngeal tube. Two PSC patients had recurrent cholangitis in the follow up. There was one stent migration in 90 day follow up. With all the HJ anastomotic strictures resolution of strictures seemed to be achieved.

CONCLUSIONS

Treatment of biliary or anastomosis strictures in altered anatomy is complex and time consuming. The biodegradable stent, which can be passed through working channel of a long enteroscope, seems promising in the treatment of these strictures. The benefit is that no stent removal is needed.

Для цитирования: Lindström Outi, Udd Marianne, Rainio Mia, Nuutinen Hannu, Jokelainen Kalle, Kylänpää Leena. Benign biliary strictures treated with biodegradable stents in patients with surgically altered anatomy using double balloon enteroscopy.. Scandinavian journal of gastroenterology. 2020. DOI: 10.1080/00365521.2020.1806351.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.