Laparoscopic pyeloplasty using endoscopic GIA stapler for ureteropelvic junction obstruction.

Araki Hidemori, Ono Yoshinari, Hattori Ryohei, Goto Momokazu, Yamamoto Tokunori, Kimura Toru, Ohshima Shinichi

СтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: We applied laparoscopic pyeloplasty in 10 patients with ureteropelvic junction (UPJ) obstruction. To evaluate the efficiency and safety of this procedure using an endoscopic GIA stapler, the clinical outcomes and our procedures are presented.

PATIENTS AND

METHODS

From August 1996 to March 2003, eight female and two male patients with a mean age of 22.3 years suffering from UPJ obstruction diagnosed by various combinations of ultrasonography, excretory urography, retrograde ureteropyelography, CT, and MRI were treated with laparoscopic dismembered Anderson-Hynes pyeloplasty with resection of a dilated redundant renal pelvis. In six cases, an endoscopic gastrointestinal automatic stapler (Endo-GIA) was used. The procedure was performed via an extraperitoneal approach in two cases and a transperitoneal approach in eight.

RESULTS

Laparoscopic pyeloplasty was successful in all patients, including the six treated using an Endo- GIA stapler. The mean operating time was 291 minutes, and the mean anastomotic time was 105 minutes, with a mean estimated blood loss of 44 mL. Postoperative complications occurred in five cases: anastomotic urinary leakage in two and pyelonephritis in three. The mean time to full convalescence in the entire series was 22 days. No urolithiasis occurred in the patients treated with the Endo-GIA stapler during the follow-up period of 2 to 76 (mean 22) months.

CONCLUSIONS

Laparoscopic dismembered pyeloplasty including the Endo-GIA stapler technique is an efficient and safe procedure that provides excellent results for extrinsic or complicated UPJ stenosis. The risk of stone formation has not yet been determined.

Для цитирования: Araki Hidemori, Ono Yoshinari, Hattori Ryohei, Goto Momokazu, Yamamoto Tokunori, Kimura Toru, Ohshima Shinichi. Laparoscopic pyeloplasty using endoscopic GIA stapler for ureteropelvic junction obstruction.. Journal of endourology. 2005. DOI: 10.1089/end.2005.19.143.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.