MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1089/089277904322836587

Медицинская библиотека · Journal of endourology · 2004

Efficacy and safety of the Healthtronics LithoTron lithotripter.

Jain Pankaj M, Goharian Nazli, Weiser Adam C, User Herbert M, Kimm Simon, Kim Samuel C, Stern Jeffrey A, Pazona Joseph, Wambi Christopher, Yap Ronald, Blunt Lynn W, Nadler Robert B

Оценочное исследованиеСтатьяПеревод пока не подготовлен

Аннотация

PURPOSE: To evaluate our experience with the LithoTron lithotripter (Healthtronics, Atlanta, GA), a dry portable system that utilizes a spark-gap electrode as an energy source.

PATIENTS AND

METHODS

We prospectively evaluated the first 312 treatments performed on 199 men and 99 women with an average age of 43.5 years (range 4 months-80 years), over a 25-month period between May 1999 and June 2001. Of the 468 stones treated, 136 were located in the ureter, 52 in the renal pelvis or ureteropelvic junction, and 230 in the kidney; the sites of 50 were not specified in our database. The average stone size was 8.0 mm (range 1-40 mm). Follow-up included a plain (KUB) film, CT scan, or intravenous urogram (IVU) and was available for 256 patients. "Stone free" was defined as no fragments visible on postoperative images. The mean radiographic follow-up was 74 days (range 0-866 days). Data collection was initially done manually by data sheets, but a Web-based medical database application was developed in order to enter, store, retrieve, and analyze the data more efficiently.

RESULTS

The average number of shocks delivered per renal unit was 2689 at 25.8 kV. Seventy-five percent of the procedures were performed with intravenous sedation. Two thirds (169/256) of the patients were rendered stone free with one treatment. According to size, 71% (209/294) of stones <1 cm, 57% (39/68) of stones between 1.0 and 1.5 cm, and 22% (8/36) of stones >1.5 cm were eliminated. There were 23 patients who required further treatment; from the available data, 18 of them are currently stone free. Perioperative complications occurred in 6 patients (2%). No patient had worsening renal function or new-onset hypertension. The effectiveness quotient was 59.3%.

CONCLUSION

The LithoTron lithotripter is satisfactory for stones <1 cm.

Для цитирования: Jain Pankaj M, Goharian Nazli, Weiser Adam C, User Herbert M, Kimm Simon, Kim Samuel C, Stern Jeffrey A, Pazona Joseph, Wambi Christopher, Yap Ronald, Blunt Lynn W, Nadler Robert B. Efficacy and safety of the Healthtronics LithoTron lithotripter.. Journal of endourology. 2004. DOI: 10.1089/089277904322836587.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.